Copyright © Risknowlogy®. All rights reserved. v9
Does it give you the risk reduction you need?
‣
If you have good data
‣
From the initial design (assuming you still have the documentation)
‣
From proof tests (how often did you find dangerous failures - tells you PFD)
‣
From demands (supports the data from proof tests - how often did it work)
‣
If you don’t have good data
‣
You have to open the “black box”
‣
Get the drawings and go inspect to work out what you have (and how it works)
‣
Use 3rd party databases or - if all else fails - FMEA
‣
Be very careful that the numbers you use are relevant and statistically sound
‣
Don’t forget the other assumptions in the LOPA
‣
Initiating event frequency
‣
Other IPL’s
‣
Demand rate
13