ICONS
575
Adjustability: Fitting
· Slewing range
· Pivoting range
Adjustability: Lamp/part of fitting
· multi-directional
· multi-directional up to the indicated value
Pendant cable length
for pendants in ft
Installation depth
in inches
[In case an installation box is included, the dimensions refer
to its size.]
Weight
of the product in lbs
Beam angle
symmetrical / focusable / asymmetrical
We are happy to provide you with a
light distribution curve
for the respective product on request.
· Mounting surface on the wide side
· Mounting surface on the small side [vertical]
· Mounting surface on the small side [horizontal]
340°
180°
20
9.5
50° 15°–30°
9.5
60°
PRODUCT FEATURES
SPEZIFIC DATA – RECESSED FITTINGS
SAFETY-RELATED INFORMATION
APPLICATION / INSTALLATION
90°F
0.8 t
Installation cutout
in inches
Shape and size
Heat development
on the inground fitting’s surface
Weight capacity
of the product up to the indicated value in
tons. Measures are based on installation in concrete.
9.5/22 9.5/22 7.2
· Application
exclusively
indoors
Lamp suitable for application in fittings
without
protective glass.
LED equipment
Number and type of built-in LEDs.
Dimmable
LED
35 pcs.
Fittings with built-in LEDs
LED cannot be changed in the luminaire.
LED can be replaced with the help of additional tools.
1.5 ft
Reflector lamps | Multi mirror lamps [cool beam]:
The main heat is emitted towards the back side of the
reflector. Reduced thermal load at the light beam.
Reflector lamps | Direct beam lamps [no cool beam]:
Thermal load at the light beam, therefore hardly any heat
development on the back side of the reflector.
Average
life span
of a lamp or fitting in hours.
[For fittings with integrated LED lamps:
Average life span of the
whole product
in hours.]
Maximum distance between wires
for low-voltage wire systems in inches
16A
max.
7–12
2500
115°F
5 J
ta 40°
ta
-25°–+40°
max.10
350
mA
12VDC
120VAC
120VAC
12VDC
120VAC
Maximum current carrying capacity
Thermal fuse
with temperature indication in °F
Lamp is equipped with
UV protection
.
· Allowed
surrounding temperature
in °F
· Allowed
temperature range
in °F
Impact resistance
of the product up to the indicated value in Joule
Through-wiring …
· possible.
· possible up to the indicated number of fittings.
Operation voltage
· High-voltage 120VAC
· Integrated converter for 120V alternating voltage to 350mA
direct current
· Low-voltage with voltage converter for high-voltage systems
120VAC/12VDC
· Low-voltage 12VDC
Cable diameter
in inches
Independent converter
[Electronic transformer for application outside of fittings as well.]
Specification of ETL listing
Dry / Damp / Wet
Mounting space
· Wall [with respective accessories]
· Ceiling
· Floor
· Recessed
Module
1 COB LED