Previous Page  575 / 578 Next Page
Information
Show Menu
Previous Page 575 / 578 Next Page
Page Background

ICONS

575

Adjustability: Fitting

· Slewing range

· Pivoting range

Adjustability: Lamp/part of fitting

· multi-directional

· multi-directional up to the indicated value

Pendant cable length

for pendants in ft

Installation depth

in inches

[In case an installation box is included, the dimensions refer

to its size.]

Weight

of the product in lbs

Beam angle

symmetrical / focusable / asymmetrical

We are happy to provide you with a

light distribution curve

for the respective product on request.

· Mounting surface on the wide side

· Mounting surface on the small side [vertical]

· Mounting surface on the small side [horizontal]

340°

180°

20

9.5

50° 15°–30°

9.5

60°

PRODUCT FEATURES

SPEZIFIC DATA – RECESSED FITTINGS

SAFETY-RELATED INFORMATION

APPLICATION / INSTALLATION

90°F

0.8 t

Installation cutout

in inches

Shape and size

Heat development

on the inground fitting’s surface

Weight capacity

of the product up to the indicated value in

tons. Measures are based on installation in concrete.

9.5/22 9.5/22 7.2

· Application

exclusively

indoors

Lamp suitable for application in fittings

without

protective glass.

LED equipment

Number and type of built-in LEDs.

Dimmable

LED

35 pcs.

Fittings with built-in LEDs

LED cannot be changed in the luminaire.

LED can be replaced with the help of additional tools.

1.5 ft

Reflector lamps | Multi mirror lamps [cool beam]:

The main heat is emitted towards the back side of the

reflector. Reduced thermal load at the light beam.

Reflector lamps | Direct beam lamps [no cool beam]:

Thermal load at the light beam, therefore hardly any heat

development on the back side of the reflector.

Average

life span

of a lamp or fitting in hours.

[For fittings with integrated LED lamps:

Average life span of the

whole product

in hours.]

Maximum distance between wires

for low-voltage wire systems in inches

16A

max.

7–12

2500

115°F

5 J

ta 40°

ta

-25°–+40°

max.10

350

mA

12VDC

120VAC

120VAC

12VDC

120VAC

Maximum current carrying capacity

Thermal fuse

with temperature indication in °F

Lamp is equipped with

UV protection

.

· Allowed

surrounding temperature

in °F

· Allowed

temperature range

in °F

Impact resistance

of the product up to the indicated value in Joule

Through-wiring …

· possible.

· possible up to the indicated number of fittings.

Operation voltage

· High-voltage 120VAC

· Integrated converter for 120V alternating voltage to 350mA

direct current

· Low-voltage with voltage converter for high-voltage systems

120VAC/12VDC

· Low-voltage 12VDC

Cable diameter

in inches

Independent converter

[Electronic transformer for application outside of fittings as well.]

Specification of ETL listing

Dry / Damp / Wet

Mounting space

· Wall [with respective accessories]

· Ceiling

· Floor

· Recessed

Module

1 COB LED