Target volumes – PRV

The use of a PRV around an Organ at Risk is relevant for OARs

whose damage is especially dangerous

This applies to organs where loss of a

small

amount of tissue

would produce a

severe

clinical manifestation

A PRV is relevant for an OAR with serial organisation (almost

exclusively)

Spinal cord

Brain stem

Optic pathway

A PRV is

not

the same as a plan optimising volume