4/119
Articles marked ◊ are not held in stock, procurement is effected at short notice.
Measuring
Equipment
4
Design:
Easy handling by means of high-resolution colour display and
proven user guidance,
wireless Bluetooth connection
, integrated
standard in drive unit, large measurement range of 350 µm. Automatic
function for profile recognition and corresponding norm-compliant
setting of filters and respective scan lengths, integrated memory for
the results of approx. 40,000 measurements and 30 profiles, 16
languages (3 of which are Asian), integrated thermal printer with
highest print quality, output of R-profile via thermal printer, protocol
output at press of a button or automatically.
Data transfer of the results via USB interface to computer, evaluation
of the most common indicators, indicator lists (e.g. material share),
integrated memory for results and profiles, tolerance monitoring,
printing of R-profile (ISO/ASME/JIS), P-profile (MOTIF), material
share curve, results protocol, setting of unsymmetrical cut level for tip
counting, measuring unit (µm/inch) and standards (ISO/JIS/ASME/
MOTIF) selectable, individual measuring routes as well as shortened
cuttoff selectable, lock for device setting, built-in battery with power
management, plug-in power supply with exchangeable adapters for
worldwide use, date and time for protocoling, extendable stationary
measuring station, use of probe rows, software MarSurf PS1/M
300 Explorer for protocoling. Supplied with standard probe, normal
calibration note, 1 roll of thermal paper, probe protection, face prism,
height adjustment, wide-range power supply with 3 adapters, 2 USB
cables (for the connection to the computer and the use with cable),
hexagon screwdriver, in transport bag.
Application:
For shafts, enclosure parts, large machines, large
workpieces, milling and turning parts, ground and honed workpieces,
in production and manufacturing areas at the machine for the quick
determination of the roughness depth of the workpiece in or on the
machine.
Note:
Probes, measurement stands and geometry
standards from
Ç
4/120.
Analysis software SW PS1/M300 Explorer
(Bestell-Nr. 4942 0060,
Ç
4/130).
Data cable RS 232 (Order No. 4942 0055,
Ç
4/130).
Data cable USB incl. software (Order No. 4246 0190,
Ç
4/54).
Data cable Digimatic (Order No. 4246 0185,
Ç
4/54).
Order
No.
Sensor tip
mm
4870
Connection
0020
0.002
4400.00 ◊
Bluetooth
0025
0.002
4400.00 ◊
Cable bound
(W490)
Mobile roughness gauge
Technical data:
Indicators
Ra, Rz (Ry (JIS) entspr. Rz), Rz (JIS), Rq, Rmax, Rp, RpA (ASME), Rpm (ASME), Rpk, Rk, Rvk, Mr1,
Mr2, A1, A2, Vo, Rt, R3z, RPc, Rmr (tp (JIS, ASME) acc. Rmr), RSm, RSk, S, CR, CF, CL, R, Ar, Rx, Rv
Horizontal scale
dep. on cut-off
Protocol contents
R-Profile, MRK, P-Profile (MOTIF), depiction of results
LC Display
High-resolution, 3.5", 320 x 240 pixels
automatic/manual. protocol with time
Printer
Thermal printer, 384 point/horizontal line, 20 chars/line
Print speed
approx. 6 lines/second acc to approx. 25 mm/s
Thermal paper
∅ 40.0 mm– 1.0 mm, width 57.5 mm– 0.5 mm, external coating
Calibration function
dynamic
Languages
German, English, French, Italian, Spanish, Portuguese, Dutch, Swedish,
Russian, Polish, Czech, Japanese, Chinese, Korean, Hungarian, Turkish
Connections
Drive unit, plug-in power supply, USB, MarConnect
Data interface
RS 232, USB, Digimatic, USB A
Rel. humidity
30 % to 85 %
Protection type
M 300 = IP 42, RD 18 = IP 40
Temperature range for operation/work
+5 °C to +40 °C
Temperature range for storage
–15 °C to +55 °C
Power supply
NiMH accumulator for approx. 1000 measurements (depending on number and length of
protocol printouts), plug-in power supply with input voltage 90 to 264 V and three network adapters
Dimension (L x W x H) of drive unit
130 mm x 70 mm x 50 mm
Dimensions (L x W x H) of the evaluation device
190 mm x 140 mm x 75 mm
Weight
4.1 kg
Measurement principle
Profile method
Probe
Inductive skid probe
Measurement range
350 µm, 180 µm, 90 µm (automatic change)
Profile resolution
8 nm
Filter in accordance with ISO/JIS
Gaussian, Ls filter (exchangeable)
Cutoff Ic in accordance with ISO/JIS
0.25 mm, 0.8 mm, 2.5 mm
Number n of individual measurement paths in acc. with ISO/JIS selectable: 1–5
Shortened cutoff in accordance with ISO/JIS
selectable
Probe route Lt in accordance with ISO/JIS
1.75 mm, 5.6 mm, 17.5 mm
Total route in acc with ISO/JIS
1.25 mm, 4 mm, 12.5 mm
Keying speed
0.5 mm/s
Measuring force
approx. 0.7 mN
Weight of drive unit
approx. 0.3 kg
Weight of evaluation device
approx. 1 kg
IP 42
RS232
USB
Digimatic
4870 0020
4870 0025
m
Roughness gauges