Table of Contents Table of Contents
Previous Page  364-365 / 596 Next Page
Information
Show Menu
Previous Page 364-365 / 596 Next Page
Page Background

24

Table 2016.2A (cont’d.)

: Comparative Results for the Detection of

Listeria

in 125 g Deli Turkey Test Portions by the 3M

MDA 2 -

Listeria

Method vs.

1

USDA/FSIS MLG Chapter. 8.09 in a Collaborative Study (Low Inoculum Level)

2

Statistic

Matrix/

Inoculation

Level

Laboratory

Candidate presumptive

(CP)

Candidate confirmed (CC)

Candidate result (C)

Reference method (R)

C vs. R

N

X

POD

(CP)

N

X

POD

(CC)

N

X

POD

(C)

N

X

POD

(R)

dLPOD

(C,R)

dLPOD

(CP,CC)

Deli

Turkey

1

12

7

0.58

12

7

0.58

12

7

0.58

12

6

0.50

0.08

0.00

2

12

7

0.58

12

6

0.50

12

6

0.50

12

5

0.42

0.08

0.08

3

12

4

0.33

12

4

0.33

12

4

0.33

12

5

0.42

-0.08

0.00

4

12

5

0.42

12

5

0.42

12

5

0.42

12

4

0.33

0.08

0.00

5

12

6

0.50

12

6

0.50

12

6

0.50

12

6

0.50

0.00

0.00

6

12

7

0.58

12

7

0.58

12

7

0.58

12

6

0.50

0.08

0.00

7

12

7

0.58

12

7

0.58

12

7

0.58

12

6

0.50

0.08

0.00

8

a

NA NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

9

12

8

0.66

12

8

0.66

12

8

0.66

12

6

0.50

0.16

0.00

10

a

NA NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

MPN/

Test

Portion

0.63

0.49

0.80

11

12

7

0.58

12

6

0.50

12

6

0.50

12

7

0.58

-0.08

0.08

12

12

5

0.42

12

5

0.42

12

5

0.42

12

4

0.33

0.08

0.00

13

12

5

0.42

12

5

0.42

12

5

0.42

12

5

0.42

0.00

0.00

Estimate

All

132

68

0.52

132

66

0.50

132

66

0.50

132

60

0.45

0.04

0.02

LCL

0.43

0.41

0.41

0.37

-0.08

-0.11

UCL

0.60

0.59

0.59

0.54

0.17

0.14

s

r

b

0.51

0.51

0.51

0.51

LCL

0.45

0.46

0.46

0.46

UCL

0.52

0.52

0.52

0.52

s

L

c

0.00

0.00

0.00

0.00

LCL

0.00

0.00

0.00

0.00

UCL

0.15

0.14

0.14

0.11

s

R

d

0.51

0.51

0.51

0.51

UCL

0.46

0.46

0.46

0.46

LCL

0.52

0.52

0.52

0.52

P

T

e

0.8762

0.9123

0.9123

0.9829

a

N/A – Laboratory did not participate or submit data for this matrix

3

b

Repeatability Standard Deviation,

c

Among-Laboratory Standard Deviation,

d

Reproducibility Standard Deviation,

e

P

T

Value = Homogeneity test of laboratory PODs

4

LCL – Lower Confidence Limit; UCL – Upper Confidence Limit

, N = number of samples tested, X = number of test samples with a positive result (presumptive or confirmed)

5

6

7

8