NASCOM DATABOOK 2014 - page 50

Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 |
2
DWG No. 130212-02 Rev. 1
.750
19.05
4.250
107.95
.750
19.05
2X .150
3.81
3.500
88.90
.750
19.05
.750
19.05
END
VIEW
TOP
VIEW
FRONT
VIEW
BOTTOM
VIEW
END
VIEW
4.250
107.95
.750
19.05
.750
19.05
2X .150
3.81
3.500
88.90
.750
19.05
BOTTOM
VIEW
FRONT
VIEW
TOP
VIEW
DIMENSIONS - IN [mm]
INSTALLATION INSTRUCTIONS
Note: High Security model – Dots on switch and magnet must be aligned for correct operation.
Position the switch on the door/window frame in the desired location as close to the movable part of the door /window as possible.
Mark the switch mounting screw locations and drill the mounting screw holes using a drill adequately sized for #6 self-tapping screws.
Connect the alarm circuit leads to the terminals on the switch and test the system for correct operation.
Install screws and tighten to mount the switch on the door/window frame.
Position the magnet on the movable part of the door/window, align the magnet with the switch as close as possible. For steel door or
window applications, use the enclosed spacer under the magnet.
Mark the magnet mounting screw locations and drill the mounting screw holes using a drill adequately sized for #6 Self-tapping screws.
Install screws and tighten to mount the magnet on the door/window.
SWITCH
MAGNET
4.250
107.95
.750
19.05
3.500
88.90
2X .150
3.81
.125
3.18
SPACER
SPDT, SINGLE POLE DOUBLE THROW
WIRING SCHEMATIC
SWITCH
CONTACT
SWITCH
CONTACT
DUAL CLOSED LOOP,
NORMALLY OPEN CONTACTS
OPEN LOOP,
NORMALLY CLOSED CONTACT
CLOSED LOOP,
NORMALLY OPEN CONTACT
SPDT, SINGLE POLE DOUBLE THROW
COMMON
(BROWN)
NC, OPEN LOOP (WHITE)
NO, CLOSED LOOP (RED)
COMMON
(BROWN)
DPDT, DOUBLE POLE DOUBLE THROW
COMMON
(BROWN)
NC, OPEN LOOP (WHITE)
NC, OPEN LOOP (WHITE)
NC, OPEN LOOP (WHITE)
NO, CLOSED LOOP (RED)
N400T
INDUSTRIAL BAR SCREW TERMINAL SWITCH SET
1...,40,41,42,43,44,45,46,47,48,49 51,52,53,54,55,56,57,58,59,60,...232