Previous Page  176-177 / 2239 Next Page
Information
Show Menu
Previous Page 176-177 / 2239 Next Page
Page Background

A typical linac of today

3

Varian Clinac

®

Engineered for Clinical Benefits

1 Gridded Electron Gun

Controlsdose rate rapidly and accurately.Permits precise

beam control for dynamic treatments, since gun can be gated.

Removable for cost-effective replacement.

2 Energy Switch

Patented switch provides energies within

the full therapeutic range,at consistently high, stable dose rates,

even with low energy x-ray beams. Ensures

optimum performance and spectral purity at both energies.

3 Wave Guide

High efficiency,side coupled standingwave accelerator guide

with demountable electron gun and energy switch.

4 Achromatic 3-Field Bending Magnet

Unique design with fixed ± 3 %energy slits ensures exact

replication of the input beam for every treatment.

The 270

o

bendingsystem, coupled withVarian’s3-dimensional

servo system, provides for a2 mm circular focal spot size

for optimal portal imaging.

5 Real-Time Beam Control Steering System

Radial and transverse steeringcoils and a real-time feedback system

ensure that beam symmetry iswithin ± 2 %at all gantr y angles.

6 Focal Spot Size

1

2

3

4

5

6

7

8

9

10

Utrecht 2016

Even at maximum dose rate – and any gantry angle – the circular

focal spot remains less than 2 mm, held constant by a focus solenoid.

Assuresoptimum image quality for portal imaging.

7 10-Port Carousel

New electron scattering foils provide homogeneous electron beams

at therapeutic depths. Extraports allow for future development

of specialized beams.

8 Ion Chamber

Dual sealed ion chambers with 8 sectors for rigourousbeam control

provide two independent channels, impervious to changes

in temperature and pressure.Beam dosimetry is monitored to be

within ± 2 %for longterm consistency and stability.

9 Asymmetric Jaws

Four independent collimatorsprovide flexible beam definition

of symmetric and asymmetric fields.

10 Millennium

Multi-Leaf Collimator

Dynamic full field high resolution 120 leaf MLC with

dual redundant safety readout for most accurate conformal beam

shapingand IMRT treatments.

11 Electronic Portal Imager

High-resolution PortalVision

aS1000 Megavoltage imager mounted on a

robotic arm for efficient patient setup verification and IMRT plan QA.

12 On-Board Imager

®

kV X-ray source (12a) and high-speed, high-resolution X-ray detector (12b)

mounted on two robotic arms orthogonal to the treatment beam for

Image Guided Radio Therapy (IGRT).The unique system provides kV imaging

at treatment and includes radiographic,fluoroscopic and Cone Beam CT

image acquisition and patient repositioningapplications.

11

12a

12b