Commercial Refrigeration
Features heavy-duty,
synchronous
motor, adjustable defrost frequency/
duration and steel case with electrical
knockouts in sides, back and bottom.
Temperature range -35°F to 175°F. 60
Hz. 40A non-inductive @ 120V, 208V or
240V AC. UL listed.
Defrost Controls, Adjustable Timers & Terminators
Unit#3078066
Drop-In
Replaces SUPCO
S814520.120V/240V.
Unit#3078044
For use with defrost heaters, water heat-
ers, indoor/outdoor lighting systems,
motors and pumps. Features adjustable
intervals, LED indicators, fast cycle button
and timer reset connection. Includes (2)
sets of contacts. Screws not included.
Unit21
Sub Zero
Thermistor assembly used on Sub-
zero® models.
Unit#2752001
Three Wire
For use on air conditioners and refrigeration units. Heat sensored brass
construction. Contains brass cylindrical tube, stainless set screw,
wrench and anti-arcing spacer.
Unit#4281019
For temperature control in refrigeration, defrost, ice maker, heat pump,
air conditioning and dehumidifer applications. Sealed construction.
Features 24” leads.
DEFROST CONTROLS
Order
No.
Volts
Switching
NO / NC
Time Initiated / Time Terminated
S804100120
1 / 2
S804120240
1 / 2
S804500120
1 / 1
S804520240
1 / 1
8043-20208 / 240
2 to 4 / 1 to 3
8047-00120
2 to 4 / 3
8047-20208 / 240
2 to 4 / 3
Time Initiated / Temperature or
Pressure Terminated
S814100120
1 / 2
S814120240
1 / 2
S814500120
1 / 1
S814520240
1 / 1
8143-00120
2 to 4 / 1 to 3
8143-20208 / 240
2 to 4 / 3 /1 to 3
DEFROST CONTROLS
Order
No.
Desc.
M814520Defrost control
ADJUSTABLE TIMERS
Order
No.
Volts
Max. Motor Switching HP
Max.
Switching
Amps
EDT13120
1
27
EDT13-20220
2
25
THERMISTOR
Order
No.
Replaces
TH41504204150
COMPRESSOR TERMINAL REPAIR KITS
Order
No.
Gauge
For Unit
Sz. Tons
TLC388
5+
TLC31010
3 to 5
TLC31212
1 to 3
DEFROST TERMINATORS
Order
No.
Open
Temp. °F
Close
Temp. °F
L4545
25
L5050
30
L5555
35
L6060
40
L7070
50
CL4545
25
CL5050
30
CL5555
35
CL6060
40