Case #1 – Prostate patient
•
35 fractions
•
Assumptions
– Delineation error = 1 mm (SD)
– Registration error = 1 mm (SD)
– Intrafraction motion = 1 mm (SD)
– Offline: Divide systematic error by 3, random stays the same
– Online: Both systematic and random are 0 mm