Previous Page  44 / 192 Next Page
Information
Show Menu
Previous Page 44 / 192 Next Page
Page Background

,'

Bantam

Thermocouples

-

Swaged

or

MGO

Assemblies

Swaged

or

MgO thermocouples have

a

metal sheath and

compacted

Magnesium oxide

pourder

for insulation.

Since

they

have

ceramic

insulation,

swaged

thermocouples can

go

to a much

higher

temperature than

Miniature

and

Probe

types.

Swaged

thermocouples

are

very flexible

and can safe-

ly

handle

a

bend

around

a

surface two times the

diameter of the sheath.

Note: lf

you

would

like to order

a

Type

E,

J,

N,

or

Type T assembly,

iust

substitute

the

K

with

a

E,

J, N,

or

T

in

the

part numbers listed

on

this

page.

Double element assemblies are also

available. Add

a

"D"

to

the

part

num-

ber.

Example:

1

8K4S9D-G-HX-*

Swaged thermocouples

are also

available

in

Types,

C,

B,

R, and

S.

Sheath materials

other

than the common ones listed

at

the bottom

of

this

page can

be

ordered. Some

of

these

include;

Molybdenum,

TantalLlm,

or

Hastelloy,

phone one of

our

sales

engineers for

details.

Temperature

Limits

Thermocouples

are made

with high

purity

Magnesium oxide

insulation and conductors

which

are

within special

limits of

error.

314

8

1090'c

2000'F

U2

11

1090'c

2000"F

3tB

I4

1090'c 2000'F

5t16

I6

1090'c 2000'F

Tt4

18

87-Oec

980'C

1800'F

3tr6

20

870'C

1600'F

,t: : :,:::

1:

::

:1.:

'2'3'00,1F

1/8

24

B7O"C

1600'F

23..0

F

U16

30

800'c

1470"F

230CI"F

Note: Limits

are

based on Type K thermocouples

Swaged

or

MgO,

Hex

Fitting

Swaged thermocouple assemblies with

a hexfitting

(HX)

are

used where a

316

stainless steel

112"

x

112"

NPT fitting is desirable for mounting to the process and to the connection

head.

The

hex

fittings are welded to the sheath for strength and proper

sealing. A

grounded junction is

standard

for rapid

response. A

1/8" NPT

316

stainless steel compression fitting (CF) can also

be

specified

by

adding CF

to the end of the part

number.

8

11

14

16

18

20

24

314

112

318

5i16

114

3/16

118

19.1

12.7

9.5

7.9

6.4

4,8

3.2

8K4S9-G.HX-

11K4Sg.G.HX

14K4Sg.G.HX

16K4Sg.G.HX

18K4Sg-G-HX

20K4Sg.G.HX

24K4Sg.G.HX

Swaged

ot

MgO,

Hex

Fitting

& Head

Swaged thermocouple assemblies with

a

hex

litting

(HX)

are

used where

a 316

stainless steel

112"

x112"

NPT

fitting is desirable

for

mounting to the process and to the connection

head.

The

hex

fittings are welded to the sheath for strength and proper

sealing.

These assemblies also

come with our (SH ) style standard aluminum weatherproof

head.

A

grounded junction is

standard

for rapid

response. A

1/8" NPT

316

stainless steel compression fitting (CF) can also

be

specified

by

adding

CF

to the end of the part

number.

8

11

14

16

18

20

24

314

112

318

5116

114

3/1 6

118

19.1

12.7

9.5

7.9

6.4

4.8

3.2

8K4Sg-G-HX-.SH

11

K4S9.G-HX.-SH

14K4Sg.G.HX.-SH

16K4Sg.G.HX.*SH

18K4S9-G.HX.-SH

20K4Sg.G-HX.-SH

24K4Sg.G.HX.-SH

Swaged

or

MgO, Compression

Fitting

& Head

Swaged thermocouple assemblies with our (SH ) sVle standard aluminum weatherproof head.

A

grounded junction

for rapid

response

and

1/8" NPT

316

stainless steel compression fitting

(CF) are standard.

8

11

14

16

18

20

24

314

112

318

5/1 6

114

3/16

118

1

9.1

12.7

9.5

7.9

6.4

4.8

3.2

8K4Sg-G.*SH-CF

11K4S9.G.-SH-CF

14K4S9.G.-SH.CF

16K4S9.G.-SH.CF

18K4S9.G.-SH-CF

20K4Sg.G.-SH.CF

24K4Sg.G.-SH.CF

Swaged

or

MgO,

Transition

Fitting

Swaged transition

assemblies

have extension wires attached to the

thermocouple.

This is

beneficial when the instrument

is

located some distance from the area where

the

temperature

is

being measured.

A

relief spring

is

installed to give protection to the potted

junctions.

A

grounded junction and

3"

of split leads are

standard.

A

1/8" NPT

316

stainless steel

compression

litting

(CF) can also be

specified

by adding

CF

to the end of the part

number.

18

20

24

114

3/16

118

6.4

4.8

3.2

18K4S9.G.Y.TR.X

2OK4Sg.G-Y-TR.X

24K4Sg-G.Y.TR.X

Swaged

or lllgO,

Armored

Cable

Swaged transition

assemblies

have extension wires attached to the

thermocouple.

This is

beneficial when the instrument

is

located

some

distance from the

area

where the temperature is

beingmeasured.

Armoredcableisaddedontheleadwireforprotectionagainstwiredamage.

A

grounded iunction and

3"

of split leads are

standard.

A

1/8" NPT

316

stainless steel

compression fitting (CF) can also be

specified

by

adding CF

to the end of the part

number.

18

20

24

114

3116

118

6.4

4.8

3.2

1

8K4S9.G.Y.FEZ.X

2OK4Sg.G.Y.FEZ-X

24K4Sg.G.Y-FEZ.X

#9

alloy (600) is standard,

but

#7

(446ss), #B (304ss),

#16

(316ss),

#20

(310s)

or

#23

(2300) can

be

requested.

Just replace the

9

in

the part

number.

"Add

thermocouple length (P) as the

sufiix.

Multiples of

6" are

in stocked,

but

any

length

can be specified.

Page 44