General issues

PRV concept works best for serial structures such

as cord or brain stem which depend on D max

More complex to use for parallel structures with a

volume dependence

03/01/13

Many TPS optimization reduce dose adjacent to

where OAR is so get minimums which may be in

target areas

- ? How to compensate

- ? Allow dose to spill out in volumes away

target