MammoSite

Technically easier than IB, widespread use

FDA approved 2002, multi-lumen device approved 2009

More reproducible and better tolerated

15 cm long, 6 mm thick double lumen for inflation and Ir-192 sourse connected

to a computer-controlled HDR remote after-loader

The Ir-192 runs in central catheter in the balloon, balloon diam 1.5-4 cm

Dose prescribed 1 cm from balloon surface, usually 34 Gy/10 fr / 5 days

Balloon-based techniques: MammoSite, Axxent, Contura