Dose planning and reporting for 3D image based

APBI (GEC-ESTRO trial)

planning aim: PD = 30.1Gy (7x 4.3Gy),

V

100

= 90%,

DNR <0.35,

implant-rib distance ≥ 5mm

Major et al. 2007, Radiother Oncol 90(1):48-55

Results for 28 pts. (mean and ranges):

volume PTV:

63.1cm³ (17.2-124cm³)

D

90

PTV:

102 % (99-107 %)

D

100

PTV::

69 % (90-96 %)

DNR:

0.33 (0.25-0.41)

skin D

max

:

53 % (18-75 %)

ipsilateral lung D

max

: 42 % (7-75 %)

V5Gy: 42.6 cm³ (0-160 cm³)

V10Gy: 4.8 cm³ (0-39.5 cm³)

V15Gy: 0.5 cm³ (0-7.9 cm³)

heart D

max

:

21 % (4-40 %)

V5Gy: 8 cm³ (0-33.5 cm³)

V10Gy: 0.1 cm³ (0-0.3 cm³)

PTV: excision cavity + 20mm safety margin

D

max

skin

≥5mm

lung

heart