relays

&

power distribution

Scan for

pricing

or go to

www.delcity.net/

catalogpricing

Change Over Relays

Change over relays can be used in

applications that require Change Over

Relays, Normally Open Relays or Normally

Closed Relays.

Relays

The best solution for full voltage applications. Ideal for use with head lamps, auxiliary lamps,

fog horns, fan motors, window lifters, air conditioners, heated rear windows or a myriad of

other equipment existing on vehicles today. Engineered to deliver superior performance over

a long life.

OPERATING CHARACTERISTICS:

Permissible ambient temperature = -40°C to 125°C (-40°F to 257°F)

Mechanical Life–no load = 10,000,000 operations (frequency 18,000 operations/hr)

The following applies for all relays unless otherwise noted:

- Operating voltage = 8–16V at 12V; 16–32V at 24V

- Contact voltage drop(

1

) = Typ. 50MV at 10A

- Insulation resistance(

1

) = 20M

1

Min. (DC 500V)

- Operate time(

1

) = 20ms Max.

- Release time(

1

) = 20ms Max.

- Resistive load N.O. = 50A at 14V DC

- Resistive load N.C. = 30A at 14V DC

- Dielectric strength N.O.(

1

) = AC 500V, 50/60Hz 1 min

- Dielectric strength N.C.(

1

) = AC 500V, 50/60Hz 1 min

- Life Expectancy Mechanical = 10,000,000 operations (frequency 18,000

operations/hr)

- Life Expectancy Electrical = 100,000 operations (frequency 1,200 operations/

hr)

A change over relay switches current from one user to another. Change over

relays are used for switching from one horn to the fan, from forward to backward

movement of the sliding roof, from opening to closing electrically operated windows

and for two-stage uses such as fans and some rear window heating systems.

* ground diode accordingly

mounting bracket

part no.

description

73980

NC/NO 12 volt, 30/50 amp

mounting bracket with resistor

part no.

description

73982

NC/NO 24 volt, 15/20 amp

Resistor reduces voltage spikes which can damage

sensitive electronic equipment.

no mounting bracket

part no.

description

73984

NC/NO 12 volt, 30/50 amp

with diode

part no.

description

73986

NC/NO 12 volt, 30/50 amp

The same as 73984 with a diode. Diode eliminates voltage

spikes which can damage sensitive electronic equipment.

INFORMATION

IP54 Rated

IP54 Rated

IP54 Rated

IP54 Rated