Shielding

Aim:

to limit radiation exposure to acceptable levels and optimize

protection of staff, patients, visitors and the public

It is a

3D

problem

wall and ceiling materials and thicknesses - critical

areas close: radiology, nuclear medicine

Different considerations are required for: superficial/orthovoltage X Ray

units, simulators, CT, cobalt 60 units, linear accelerators (TBI-IMRT-

SRT), Brachytherapy, Hadrontherapy

3 steps procedure: i) establishing a design value for the effective dose in

the occupied area, ii) estimating the radiation field in the area if there were

no shielding, iii) obtaining the

attenuation factor

required to go from ii)

to i)

NCRP 49-151