Two Model Types

Knöös et al.:

A.

Models primarily based on

equivalent path length

for

inhomogeneity corrections, where

electron transport

is

not

separately

modeled

, and the density changes are sampled along

the 1D

(longitudinal)

primary rays.

Ex: Eclipse PB, OMP PB, XiO Convolution

B.

Models able to treat in an approximate way the

electron

transport as well as the secondary photon transport in the

medium

accounting for density changes, sampled along the full

three dimensions

(longitudinal and lateral)

.

Ex: Pinnacle CC, Eclipse AAA, OMP CC, XiO