Radiotherapy
ART for bladder made easy
27 patients T2-4 N0M0
32 fractions
Conventional plan with large margins on CT
scan
Scan first five fractions on CBCT
Calculate
Small (around smallest bladder volume)
Large (around all the volumes)
Medium: manually in between
Add 0.5 cm and plan
•Foroudi et al 2011