September 2015

ESTRO SABR course

IGRT Considerations (2)

RTT led process : advanced IGRT competency

Training and competency assessment

Example from RMH:

A 4 stage training programme was implemented including:

• Training session for RTT on good practice for SABR verification

• Competency based testing of matching 20 offline CBCT lung SABR

verifications.

To be assessed as competent a 90% concordance with clinicians verification

was required. An acceptable match was translocation < 2mm and rotation <

2

°

compared to the clinicians. To audit, a clinician retrospectively verified

20 patients lung SABR CBCT images matched by RTT

.

Audit of Advanced Competency for Radiographer led lung Stereotactic Ablative Body Radiotherapy (SABR) verification. David

Frost et al. Royal Marsden NHS Foundation Trust.