September 2015
ESTRO SABR course
IGRT Considerations (2)
•
RTT led process : advanced IGRT competency
•
Training and competency assessment
Example from RMH:
A 4 stage training programme was implemented including:
• Training session for RTT on good practice for SABR verification
• Competency based testing of matching 20 offline CBCT lung SABR
verifications.
•
To be assessed as competent a 90% concordance with clinicians verification
was required. An acceptable match was translocation < 2mm and rotation <
2
°
compared to the clinicians. To audit, a clinician retrospectively verified
20 patients lung SABR CBCT images matched by RTT
.
Audit of Advanced Competency for Radiographer led lung Stereotactic Ablative Body Radiotherapy (SABR) verification. David
Frost et al. Royal Marsden NHS Foundation Trust.
14