Table of Contents Table of Contents
Previous Page  337 / 560 Next Page
Information
Show Menu
Previous Page 337 / 560 Next Page
Page Background

337

Relays, Motor Kits, Cap Tubing & Duct Boosters

This information is provided “as is” without warranty of any kind by any person,

including without limitation, the owner and the publisher.

Chemicals

Charging,

Recovery

& Welding

Test Equip.,

Tools &

Service Acc.

Electrolux

& Frigidaire

GE

& Hotpoint

Whirlpool

& Maytag

Cooking

& Gas

Products

Dishwasher,

Disposer &

Water Heater

Laundry

Refrigeration

Fittings,

Venting &

Installation

Electrical

Plumbing

Property

Maintenance

HVAC/R

Motors

Unit#3078186

Ultra Start Series

For use in providing starting capability for single-

phase compressors. Features 2-wire installation,

voltage-sensing design and instant restart. 330V.

Unit#3078145

For use on single phase motor or AC/R com-

pressor up to 5 HP. Features drop-in design

and 1- to 1-1/2-second start time. Includes

screw or push-on terminals and adapters to

convert screw-on to push-on. 110V to 270V

AC, 30A.

Relays,MotorKits,CapTubing&DuctBoosters

Unit#3078127

Sleeve – SM600 Series

For use in coolers/freezers, evapora-

tors, exhaust fans and range hoods.

Features C-frame design, impedance

protection, and clockwise/counter-

clockwise rotation. Includes mounting

bracket, hub adapter, 1/4” shaft

adapter and 5/16” shaft adapter.

3000 RPM.

No. SM670.

Includes (2) fan blades.

No. SM675.

Thermal-protected design. Includes fan blade.

Unit#3078028

BC Series – Bullet® Restricto

For use with domestic and commer-

cial refrigerators or room air condi-

tioners from 1/8 HP to 5 HP.

Features soft copper capillary tubing

with precision bore (± .001).

CapTubing,SurgeArrestors,Relays&DuctBoosters

Unit#3078004

Surge protector for appliances.

Unit#3078003

24V.

Unit#3078004

For use in HVAC/R, vending machine, fan

control and business machine applications.

Features double pole/double throw, 6-termi-

nal design. CSA certified.

Unit#3078037

DB Series

For use in increasing air flow in hot and cold forced air systems. Fea-

tures thermally protected motor. Maximum operating temperature

140°F (60°C). Maximum airstream temperature 135°F (58°C). 115V,

60Hz. Includes mounting kit and templates.

HARD STARTS

Order

No.

HP

Capacitor

Size

ìF

MPR5

1 to 3

189 to 277

MPR1

3-1/2 to 5

270 to 324

POTENTIAL RELAYS

Order

No.

Dim. In.

W x L x H

SUPR

1-3/4 x 2-1/4 x 1-1/2

UTILITY MOTOR KITS

Order

No.

Volts

AC Amps

Shaft

Dim. In.

Stack

Size In.

SM670

120

0.55

3/16 x 1-1/4

5/8

SM675

120/240

1/.5

3/16 x 2-3/8

1

CAP TUBING

Order

No.

Size In.

OD x ID

10 Ft. Coil

BC1

.081 x .031

BC5

.071 x .028

12 Ft. Coil

BC2

.093 x .040

BC3

.093 x .052

BC4

.125 x .064

SURGE PROTECTORS

Order

No.

Desc.

O41000

Appliance surge protector

FAN RELAYS

Order

No.

Amps

SPST

90290

4

SPDT

90293

1

90370

12

NO/NC

90380

13

SWITCHING RELAYS

Order

No.

Coil

Volts

90342

208 / 240

DUCT BOOSTERS

Order

No.

Dim.

In.

Amps

Watts

RPM

Fan

Size In.

DB6

6 x 6

.35

30

1950

5-1/4

DB8

8 x 8

.75

60

1750

7

DB10

8 x 10

1.5

120

1300

8

DB12

9 x 12

1.5

120

1300

10