Fan Controls & Switches

352

This information is provided “as is” without warranty of any kind by any person,

including without limitation, the owner and the publisher.

Unit#3078185

Features SPDT switch, temperature adjustment and 7” extension. Full

load 5.8A @ 120V, 2.9A @ 240V. Locked rotor 34.8A @ 120V, 17.4A @

240V.

FanControls&Switches

Unit#3078185

Relay & Transformer - SPDT

For use in 4” x 4” junction boxes. Features pre-wired line voltage con-

nections, energy limiting class II transformer design and color coded

pre-stripped leads. 120V AC primary and 24V AC secondary trans-

former.

Unit#3078187

Adjustable

Features adjustable set points, activation

on pressure rise and SPDT contact

arrangement. Operating temperature

from 40 to 190°F (4.4 to 87.8°C) 5A non-

inductive 120V to 277V AC. 1 Amp pilot

duty (120 VA) @ 120V AC. UL and CSA

approved.

Unit#3078188

S106 Series

For use in controlling high-current blowers, relays and contacts at pre-

determined time interval after heater is energized. Features ambient

compensation (0°F to 200°F), 24V circuit connected heater timer and

SPST switching. 0.12A @ 24V AC.

Unit#3078189

For use in sensing positive, negative or differential air pressure. Fea-

tures SPDT contact arrangement. 1/10 HP @ 120 to 277V AC. 28 VA

pilot duty @ 24V AC, 125 VA pilot duty @ 120V AC.

nit#3078192

2-Pole

Replaces 2-pole, 30A contactors used in air handlers to control blower

motors for air conditioning and electric heat. Features non-positional

design. Includes (4) terminals and (4) screws. 24V, 30A. 50/60 Hz. UL

approved.

FAN CONTROLS

Order

No.

Temp.

Adj.

°F

L597BA

120 to 250

FAN CONTROLS

Order

No.

Desc.

90-113

Fan control center

We are continually

adding new products.

Call us with your

inquiries.

AIR PRESSURE SWITCHES

Order

No.

Range

In. / WC

RSS49813

1.0 to 4.0

RSS49511

0.25 to 1.0

TIME DELAY SWITCHES

Order

No.

Delay

on Make

Delay

on Break

S1061A40100C

35 to 45

80 to 110

S1061A4575C

30 to 50

60 to 90

S1061A5040C

45 to 55

30 to 50

S1061A5560C

50 to 60

45 to 75

S1061B6545C

60 to 70

45 to 75

AIR PRESSURE SWITCHES

Order

No.

Set Point Range

WC

Operating

Temp. Range

°F/°C

NS2000003

0.01 to 10

40 to 190 /

4.4 to 87.8

MAGNETIC LINE CONTACTORS

Order

No.

Replaces

SMC11

MARS 18001, Honeywell R850B1146

& Packard C18001