![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0952.jpg)
Vaginal top:
Applicator surface & at 5 mm
Nevelsky A, et al. Brachytherapy 2003;3(2):101-5
Thomadsen B, et al. Int J Radiat Oncol Biol Phys 1992;24:349-357
Noyes WR, et al. Int J Radiat Oncol Biol Phys.1995;31(1):79-86
Reference
Vag. Surf. D
Thomadsen 1992 135 - 145%
Nevelsky 2003 130 % - 231%
Noyes 1995
135 - 145 %
Au 2003
175 Gy
Hintz
98 Gy (distal v.)
140 Gy (upper v.)
Au SP, Grigsby PW. Radiother Oncol 2003;67(1):77-85
Mai J, et al. Int J Radiat Oncol Biol Phys
2001;51(4):1131-41
Hintz BL, et al. Int J Radiat Oncol Biol Phys 1980;6:711-716
Traditionally used for vaginal dose reporting / dose constraints
ICRU/GEC ESTRO report 89, 2016
Correlation with morbidity
not established