wiredInUSA - July 2014
7
Measure & Control
Instruments
CIM PC software:
OPTICAL FIBRES
Measurement Instruments
In line data collection,
display, record and report
Laser Interferometric Sensor
Diameter repeatability:
±0.005µm at 50kHz
Diameter uncertainty:
±0.15µm
Defect detection
75kHz
, event recording
Ultra fine air line detection, 0.3µm, 400Hz
Fibre position: ±2mm range ±0.1mm
,
1kHz
Spinning frequency profile
Fibre no circularity measurement
Non Contact Tension Measurement
(Drawing force Birefringence principle)
0-400 grams ±1gram, 1kHz
Measurement field:
4mm Ø
± 1 gr
within
10-40°C
ambient
Coating Monitor 5 axes
Absolute diameter:
±0.2µm, 400Hz
XY Positions
±0.1mm 1kHz
5 axes
Lump & Neck:
±2µm, 3.6MHz sampling
Coating asymmetry:
30Hz
Internal defect detection:
800kHz
(Airlines,
bubbles, inclusions, delaminations…)
AIR (AIRline detector)
LDS-T (Laser Diffraction Sensor for transparent product)
www.CERSA-MCI.com
LIS-Glass:
NCTM:
CM5:
Others:
INDEX