Main Office: 405-631-9701
246
Fax: 405-631-0585
E
|
WATERHEATERS
THERMOSTATIC MIXING, TEMPERING & PRESSURE REDUCING
COMBINATION FILL
VALVE AND BACKFLOW
PREVENTER
Series 911 combination fill valve and backflow
preventer consists of a Model 9D backflow
preventer and Model 1156F feed water
pressure regulator in one pre-assembled unit.
This valve is designed for use on boiler feed
lines to provide make-up water to the boiler
and prevent backflow when supply pressure
fails.
Pressure-Temperature
Maximum Temperature: 212 degrees F (100
degrees C)
Maximum Working Pressure: 100 psi (6.9
bars)
Adjustment Range: 10-25 psi (68.7 - 172.4
kPa) set at 15 psi (103.4 kPa)
Locke#
E0304
911S-M3 ½" Combination Fill
Valve And Backflow Preventer
PRESSURE REDUCING
BACKFLOW PREVENTER
Combines the quality pressure reduction of
the Cash Acme A-89 Pressure Reducing
Boiler Feed Valve with the effective backflow
prevention of the Cash Acme BFP Double-
Check Backflow Preventer. Reduces system
pressure down to 14 psi while preventing the
back-siphonage of contaminated water into
the potable water supply. Threaded (NPT)
inlet and outlet connections.
For smaller boiler feed lines where pressure
control and back-siphoning of water are
issues.
Locke#
E0320
BFAC ½" Pressure Reducing
Backflow Preventer
ANTI-SCALD
PROPORTIONAL
THERMOSTATIC MIXING
VALVE SW
Dual purpose mixing valve, provides constant
water temp. under any operating condition.
Simultaneous control of hot & cold water.
Energy savings through lower supply temp.
Anti-scald protection. Temp. lock at any
point or high/low range. Maximum 150 psi.
Maximum water temp. 212° F. Recommended
by the Gas Research Institute & NRECA.
Tested/certified under ANSI/ASSE 1016.
Locke#
E0048
MMV-UT ½" FIP anti-scald
E0049
MMV-UT ¾" FIP anti-scald
LOW TEMPERATURE
THERMOSTATIC
MIXING VALVE
Meets ASSE 1017 Code. Features include:
corrosion resistant, temperature range is
100-140° F, designed for easy maintenance,
consistent outlet temperature with changing
inlet conditions, element over travel protection,
ASSE 1017 approved, union connections for
easy installation, & saves energy by extending
hot water supply.
Locke
#
E0047
HG-110HFCHS ¾" Sweat
E0097
HG-110HTCH ¾" Threaded
HOT WATER EXTENDER
TEMPERING VALVES
Residential
. Mixes cold water & hot water. For
automatic storage water heaters it increases
draw capacity. Standard temp. range 100-
130°F. max. temp. 210°F. Max. 150 psi. All
bronze. Thermostat interchangeable.
Locke#
E0050
L-70A ½" Tempering Valve
E0051
L-70A ¾" Tempering Valve
WATER PRESSURE
REDUCING &
REGULATING VALVE
Suitable for supply water pressures up to
400 psi & can be adjusted from 25 to 75 lbs.
delivery pressure to the system. The standard
setting is 50 psi. Bronze body construction.
Maximum temperature is 180°F. Stainless
steel seat & strainer. Bypass feature. Has NPT
union inlet x NPT threaded outlet.
Locke#
M0546
N45-BU ¾" Reducing Valve
M0548
N45/35-BU 1" Reducing Valve