294

Fax: 405-631-0585

L

|

HVAC

NATURAL GAS UNIT HEATERS

NATURAL GAS UNIT HEATERS

115,000 to 400,000 BTUH

Features:

DIMENSIONS

Model No.

A

B

C

D

E

F

G

Clearances

Top

Sides

Rear

Bottom Flue

100 / 115 / 145

31

c

32

x

20

x

10½ 19

z

11

d

3¼ 6

6

18

0

6

175 / 200

31

c

32

x

23

8

10½ 22

z

13¼ 3¼ 6

6

18

0

6

230 / 250 / 300

31

c

32

x

41

8

3

n

38

m

17½ 3¼ 6

6

18

0

6

345

31

c

32

x

41

8

3

n

38

m

17½ 3¼ 6

6

18

0

6

400

31

c

32

x

41

8

3

n

38

m

22

8

3¼ 6

6

18

0

6

Locke

Code

Model

No.

Total

Input,

BTUH*

Total

Output

BTUH

Air

Vol.

CFM

Air Throw

at 8 Ft.

Mounting

Height, Ft

Max. Mtng

Height, Ft.

(To Bottom

of unit)

Fan Diam,

Inch/ No.

of Fans/

Blades

Ship

Wt.

LB.

Net

Wt.

LB.

H.P.

AMPS

@115V/

1PH/

80HZ

RPM

Motor

Type

****

Flue

Size,

Inch

**

Gas

Connect.

Inches

***

Optional

LPG Kit

No.

L6201

SEP-100 100,000 80,500 1900 60

16 16/1/4 140 125 1/8 2.1 1075 PSC 4

½

Locke# L6705

L6203

SEP-115 115,000 92,000 1900 60

16 16/1/4 140 125 1/8 2.1 1075 PSC 4

½

LB-698-45G

Locke#-L6206

L6204

SEP-145 145,000 116,000 1900 60

20 16/1/5 150 130 1/8 2.1 1075 PSC 4

½

L6205

SEP-175 172,500 138,000 2200 65

20 16/1/5 165 145 1/8 2.1 1075 PSC 5

½

L6243

SEP-200 195,000 156,000 2200 65

20 16/1/5 165 145 1/8 2.1 1075 PSC 5

½

L6207

SEP-230 230,000 184,000 4400 80

30 16/2/5 270 255

8

(2) 4.2 1075 PSC 5

¾

LB-698-45H

Locke#-L6210

L6208

SEP-300 287,500 230,000 4400 80

30 16/2/5 285 270

8

(2) 4.2 1075 PSC 5

¾

L6209

SEP-345 345,000 276,000 4400 80

30 16/2/5 300 285

8

(2) 4.2 1075 PSC 6

¾

L6249

SEP-400 390,000 312,000 4400 80

30 16/2/5 305 285

8

(2) 4.2 1075 PSC 6

¾

LB-698-45S

Locke#-L6251

• 78% thermal efficiency & 76% seasonal

efficiency using natural gas or LPG in all

models.

• Certified by AGA and CGA and is listed by

the California Energy Code.

• All heaters have a sealed flue collector &

a power exhaust system which enables

conventional vertical venting, or horizontal

venting up to 40 feet.

• The tubular heat exchangers are

constructed of aluminized steel for superior

resistance to corrosion/oxidation. The

compact design minimizes the space

needed for the heater cabinet.

• The inshot lightweight steel burners

are maintenance free & never require

adjustment or cleaning. The entire burner

assembly is removable as 1 piece for ease

of service.

• Direct spark ignition provides 100% shut

off for safety & eliminates the need for pilot

lights.

• Cabinet is constructed of 18-22 gauge cold

rolled steel and has a baked on powder

paint finish for superior resistance to

corrosive elements.