HVAC
DUCTLESS HEAT PUMPS
FLOOR MOUNT SINGLE ZONE 9, 12 AND 15,000 BTU SYSTEMS
Floor mount systems are ideal for residential
radiator replacements or any
room with limited upper wall space.
At less than 24” high and 30”
wide, floor mount models
fit easily under a standard
window and can replace a
radiator twice its size while
producing more capacity.
Standard Features for RLFF Models
• Wireless Remote Control
• Apple Catechin Filter
• Ion Deoderizing Filter
• Sleep Timer
• 24-Hour Timer
• Auto Louver: Up/Down
• Auto Mode
• Minimum Heat Mode
• Economy Mode
• Auto Restart/Reset
• Auto Changeover
• Powerful Mode
Specifications
Locke#
Model#
Nominal
Cooling BTU/h
Nominal
Heating BTU/h
Air Circ. C.F.M.:
Running Current amps Power Use watts
Hi
Medium Low Quiet
Cooling Heating Cooling Heating
L7280
Outdoor AOU9RLFF
9,000
12,000
335 271 212 159
2.9
4.1
560 880
L7281
Indoor AGU9RLF
L7282
Outdoor AOU12RLFF
12,000
16,000
335 271 212 159
4.2
6.7
970 1440
L7283
Indoor AGU12RLF
L7284
Outdoor AOU15RLFF
14,200
18,000
383 306 235 159
5.1
7
1130 1580
L7285
Indoor AGU15RLF
Accessories
L7339
UTY-RNNUM Wired Remote Control for Wall Mounts
WALL MOUNTED HIGH-SEELR 9, 12 AND 15,000 BTU SYSTEMS
Energy Saving Program:
If you leave the room without turning the unit off, ESP knows that you
left and 20 minutes later, set temperature is increased by 4°F when cooling and reduced by 8°F
when heating. When you come back to the room, it returns to previous operating mode.
High Performance Heating:
Heating capacity at low outdoor temperatures was improved by
adopting a large heat exchanger and a high capacity compressor. Rated heating capacity is
maintained down to 20°F. This new model can operate down to -5°F.
Standard Features for RLS2 Models
• Wireless Remote Control
• Apple Catechin Filter
• Ion Deodorizing Filter
• Sleep Timer
• 24 Hour Timer
• Weekly Timer
• Dry Mode
• Auto Louver: Up/Down
• Auto Mode
• Powerful Operation Mode
• Minimum Heat (50°F/10°C)
• Economy Mode
• Energy Saving Program
• Quiet Mode (Indoor)
• Low Noise Mode
• Auto Restart/Reset
• Auto Changeover
• Low Ambient Cooling
• Cold Prevention
Specifications
Locke#
Model#
Nominal
Cooling BTU/h
Nominal
Heating BTU/h
Air Circ. C.F.M.:
Running Current amps Power Use watts
Hi
Medium Low Quiet
Cooling Heating Cooling Heating
L7373
Outdoor AOU9RLS2
9,000
12,000
500 394 324 194
2.7
3.7
560 800
L7372
Indoor ASU9RLS2
L7375
Outdoor AOU12RLS2
12,000
16,000
500 394 324 194
4
5.5
870 1200
L7374
Indoor ASU12RLS2
L7377
Outdoor AOU15RLS2
14,500
18,000
530 436 336 229
5.5
6.1
1210 1350
L7376
Indoor ASU15RLS2
Accessories
L7339
UTY-RNNUM Wired Remote Control for Wall Mounts