Table of Contents Table of Contents
Previous Page  322 / 1070 Next Page
Information
Show Menu
Previous Page 322 / 1070 Next Page
Page Background

Ma n Office: 405-631-9701

322

Fax: 405-631-0585

L

|

HVAC

UPFLOW, DOWNFLOW AND HORIZONTAL COILS

These coils are sized to

fit the Armstrong G1 and

G2 furnaces in upflow,

downflow applications.

All coils are flowrator metering

device.

These coils are sized to fit the Armstrong G1 and G2 furnaces in horizontal applications.

All coils are flowrator metering device.

UPFLOW/DOWNFLOW COIL SPECIFICATIONS

Locke#

Tonnage

Model

Cased Dimensions Uncased Dimensions

Supply

Opening Included

Orifice

Width Depth

L2790

1.5-2 HE31124C145B1601AP 14.5W x 20.5D x 16H 14W x 19.5D x 15H 13 18 .53

L2791

2.5-3.0 HE33136C145B1801AP 14.5W x 20.5D x 18H 14W x 19.5D x 17H 13 18 .67

L2792

3.0 HE33136C175B1801AP 17.5W x 20.5D x 18H 17W x 19.5D x 17H 16 18 .67

L2793

3.5-4.0 HE36148C175B2501AP 17.5W x 20.5D x 25H 17W x 19.5D x 23H 16 18 .76

L2794

3.5-4.0 HE36148C210B2501AP 21.0W x 20.5D x 25H 20W x 19.5D x 23H 19.5 18 .76

L2795

5.0 HE50160C210B2701AP 21.0W x 20.5D x 27H 20W x 19.5D x 27H 19.5 18 .93

L2796

5.0 HE50160C245B2701AP 24.5W x 20.5D x 27H 20.5W x 19.5D x 27H 23 18 .93

Downflow Applications- Coil face velocities above 350 fpm are not recommended.

DEDICATED HORIZONTAL COIL SPECIFICATIONS

Locke#

Tonnage

Description

Cased Dimensions

Supply

Opening Included

Orifice

Height Width

L2780

1.5-2.5 AD12130E145B2647AP 14.5H x 21.25D x 21.0W 13 19.75 .59

L2781

1.5-2.5 AD12130E175B2647AP 17.5H x 21.25D x 26.5W 16 19.75 .59

L2782

3.0 AD13136E145B2647AP 17.5H x 21.25D x 26.0W 13 19.75 .67

L2783

AD12136E175B2647AP 14.5H x 21.25D x 26.5W 13 19.75 .67

L2784

3.5-4.0 AD14148E175B2647AP 17.5H x 21.25D x 26.0W 16 19.75 .76

L2785

3.5-4.0 AD14148E210B2647AP 21.0H x 21.25D x 26.0W 19.5 19.75 .76

L2786

5.0 AD18160E245B2647AP 24.5H x 21.25D x 26.0W 19.5 19.75 .93

L2787

AD17160E210B2647AP 21.0H x 21.25D x 26.5W 19.5 19.75 .93

UNCASED EVAPORATOR COILS SPECIFICATIONS

Locke#

Coil Model

Overall Dimensions Included

Orifice

Width Depth Height

L3700

HE30124A130A0000AP 13.00 19.50 11.00 .53

L3701

HE32130A140A0000AP 14.00 19.50 13.00 .59

L3702

HE32136A140A0000AP 14.00 19.50 15.00 .67

L3703

HE34136A140A0000AP 14.00 19.50 17.00 .67

L3704

HE34142A155A0000AP 15.50 19.50 19.00 .73

L3705

HE35148A170A0000AP 17.00 19.50 21.00 .76

L3706

HE37160A200A0000AP 20.00 19.50 23.00 .93

L3707

HE49160A205A0000AP 20.00 19.50 2 5.00 .93

General Spec ficat ons

• Produced in a ISO 9002 certified

facility.

• Ratings in conformity with ARI

standard 210.

• UL Listed.

• For use with R-22 and R-410a

refrigerants.

• Coils are individually tested at

450 PSI, then pressurized and

sealed.

• Rifled Copper Tubing.

• Refrigerant connections are 3/8"

ODF liquid and 3/4" ODF (18-36

MBTUH) or 7/8" ODF (42-60

MBTUH) suction.

• Florators standard.

Additional" A" Coil Features

• Dual 3/4" FPT condensate drains

on left and right.

• Heavy gauge embossed

galvanized cabinets fully lined

with 1/2" foil faced insulation

(cased coils).

• Optional painted cabinets.

• Refrigerant connections available

on left or right.

• Up or down airflow (standard coil)

• Up, down, left or right airflow