Ma n Office: 405-631-9701

350

Fax: 405-631-0585

L

|

HVAC

Ground Water Application:

Water Temp 45° to 75°

Ground Loop Application:

Temp Range 25° to 110°

TYPICAL INSTALLATION

Unit installs upright and hooks up

conveniently to supply water system. Ideal for

closet, basement, or utility room installation.

Requires very little floor space. Can be

installed with or without return air duct.

H gh Effic ency Copper Coax al Water

Coil:

Water to refrigerant coil is completely

insulated to prevent frost build-up at low

temperature operation.

Indoor Air Coil:

Grooved copper tubing

and enhanced louvered aluminum fin for

maximum heat transfer and energy efficiency.

Coil is constructed with special corrosion

resistant hydrophilic fin stock with 2-layer

coating.

Filter Rack:

Factory installed with 2" MERV

6 pleated filter.

Thermostatic Expansion Valve:

For wide

range refrigerant control (2-way operation).

Domestic Hot Water Heat Exchanger:

Double wall vented heat exchanger, factory

installed on all models - optional GVDM-26

pump kit required for hot water heating.

Water Connections:

All water connections

on outside of cabinet with dual side

connections. Brass full swivel double o-ring

connection with 1" full flow ports.

Electric Heat:

Slide in Electric Heater

Package - up to 18KW can be field installed.

Variable Speed ECM Blower Motor:

• High Efficiency

• Soft starting - low noise on start up

• Continuous fan - will operate at 50% of

rated Stage 2 airflow

Mild Weather Operation:

Part Load Cooling

Operation will operate at 20% reduced airflow

Locke#

Capacity Model

Voltage

Range

Min.

Circuit

Amps

Compressor

Blower Motor And Evaporator Air Filters

2" Pleated

MERV 6

Shipping

Weight

Lbs.

Volts Rated Load

Amps 230/208

Lock Rotor

Amps 230/208 HP/Speed/Type Motor Amps

L5501

3 Ton GV38S2-AN 253-197 26 230/208 12.4/14.5

82/82

1/2 / 5 / ECM 2.5 / 2.95 20 x 25 x 2 (1)

345

L5502

4 Ton GV51S2-AN 253-197 32 230/208 17.4/20.6

96/96

1/2 / 5 / ECM 2.8 / 3.0 16 x 25 x 2 (2)

390

L5503

5 Ton GV61S2-AN 253-197 38 230/208 22.4/27.4

118/118

3/4 / 5 / ECM 3.8 / 4.1 16 x 25 x 2 (2)

440

L5504

6 Ton GV71S2-AN 253-197 41 230/208 24.7/28.5

150/150

3/4 / 5 / ECM 4.1 / 4.2 16 x 25 x 2 (2)

450

GEOTEC™ GV – SERIES HIGH EFFICIENCY GEOTHERMAL/WATER SOURCE,

PACKAGED STEP-CAPACITY UPFLOW HEAT PUMP — R410A

Engineered Features

Steel Cabinet:

Galvanized 20 gauge zinc

coated steel cabinet with baked-on enamel.

Multi-Capacity Two-Stage:

Simple

thermostatic control seamlessly stages

the compressor and indoor airflow rate

between full and part load capacity operation

without cycling the compressor. This helps

to maximize comfort, humidity control,

energy efficiency and overall reduction in

compressor cycling for improved system life.

Step Capacity Compressor:

Copeland

step-capacity scroll compressors are

designed for increased efficiency, quieter

operation and improved reliability.

R-410A Refrigerant:

Designed with R-410A

(HFC) non-ozone depleting refrigerant.

Liquid Line Drier:

Protects system against

moisture.

Lockout Circuit:

Built-in lockout circuit

resets from the room thermostat. Provides

commercial quality compressor protection.

High Pressure Switch:

Provides additional

protection for the system.

Control Panel:

Can be reversed to other side

for installation flexibility.

Low Pressure Switch:

Two switches

provided. Factory wired switch is for ground

water applications, alternate switch is field

connected for ground loop applications.

Locke#

L5510

EH3GSVA-A09C Heater Package for GV27S1 or GV38S1, 1 phase-60 hz, 9.0 kW @ 240V

L5511

EH3GSVA-A14C Heater Package for GV27S1 or GV38S1, 1 phase-60 hz, 13.5 kW @ 240V

L5512

EH5GSVA-A14C Heater Package for GV51S1, GV61S1 or GV71S1, 1 phase-60 hz, 13.5 kW @ 240V

L5513

EH5GSVA-A18C Heater Package for GV51S1, GV61S1 or GV71S1, 1 phase-60 hz, 18.0 kW @ 240V

L5507

GVDM-26

Hot water desuperheater pump module with ECM motor, 115v-60hz-1ph, 6' cord with 115V grounded plug, 5/8" OD

copper water line connections, can be mounted on heat pump cabinet or adjacent wall.

L5505

DORFC-2

Loop Flow Center with Cabinet, 230V-60Hz-1Ph, 2 pump, 44 Ft. Hd. @ 16 GPM, double o-ring fittings.

L5508

DORLFCK-1

Loop Flow Center Kit containing: (2) 1" barbed 90° double o-ring elbows with 1/4" FPT ports and 8603-026

pressure/temperature test plugs (for heat pump connection), (2) 1" barbed straight double o-ring fittings (for loop

flow center connection on heat pump side), (1) 12' section of 1” ID 150 PSI hose and (8) 1" SS hose clamps.

L5520

DORCL1-90

Includes (2) 90° double o-ring quick-connect cam-lever male fittings for flush attachment to loop flow center

L5521

CLB1-S

Includes (2) 1" straight barbed quick-connect cam-lever female fittings to connect to DORCL1-90

L5522

DORGHMT

Includes (1) Double o-ring x male garden hose adapter fitting for loop flow center (to burp/boost loop)

L5523

8603-027

1/4" FPT gauge adapter w/ 1/8" heavy duty probe

L5524

8603-017

FlowMeter 1-17 GPM 1" FPT

GEOTHERMAL HEAT PUMPS & ACCESSORIES