Table of Contents Table of Contents
Previous Page  447 / 1070 Next Page
Information
Show Menu
Previous Page 447 / 1070 Next Page
Page Background

Credit: 405-631-9756

447

www.lockesuppl .com

L

|

HVAC

AIR CLEANERS, ICE MACHINE SANITIZER & VENTILATORS

ENERGy RECOVERy

VENTILATOR

Provide proper levels of

ventilation with energy

savings by transferring

heat and moisture

between the exhaust

and fresh air streams.

• Includes heat/energy

transfer core, pre-

filters, and fan and

blower assembly.

• Variable fan speed control.

• Easy-to-clean core assures years of

trouble-free operation.

• Permanent (washable) pre-filters.

Temperature Recovery: 0.79

Moisture Transfer Ratio: 0.26

Airflow Capacity: 150 cfm

Locke#

Model

L7129

ER150C2004 Ventilator

FRESH AIR VENTILATION

SySTEM

Designed for easy

installation and works

with existing HVAC

fan systems. It’s an

affordable solution

to ventilation, yet it

offers best-in-class

benefits.

The Y8150A helps

meet local and

federal codes, including the new ASHRAE 62.2

standard. The intelligent algorithm calculates

the amount of ventilation needed based on

simple settings for each home. This “set it and

forget it” program means fewer callbacks for

you and optimal ventilation for the homeowner.

Locke#

L3635

Y8150A1009 Ventilator

770-1 DUAL PURPOSE AIR

SWITCHES

• Responds to positive,

negative or differential air

pressure.

• Design eliminates

“fluttering” or malfunction

due to shock or vibration

normally encountered with

“Sail Switches.”

• Wide operating range.

Locke#

L1060

Model 770-1 Dual Purpose Air

Switch

REPLACEMENT FILTER

• For use with Aprilaire Model No. 2210 and

4200 Air Cleaners (Part # 213)

• Filter can be used in 2200 and 2120 air

cleaners if Aprilaire 1213 upgrade kit has

been installed

L7152

• Factory original accordion type design for

easy storage

Locke#

L7150

213

Filter Media

L7152

1213 Model 2200 upgrade kit

REPLACEMENT FILTER

• Fits models 4400, 3310 and 2410

• May also be used in models 2400 and 2140

with upgrade kit #1413

Locke#

L7151

413

Filter Media

HUMIDIFIER HUMIDISTAT

WITH BLOWER

ACTIVATION

• For use with Aprilaire model 110, 112,

220, 224, 400, 440, 445, 445A, 448, 500,

550, 558, 560, 560A, 568, 600, 700, 760,

760A and 768 and any other humidifier that

requires 24V humidistat

• Includes Control, Outdoor Sensor, Manual

Mode Sticker, Installation Instructions and

Owners Manual

• The new Aprilaire # 60 automatic humidifier

control works in conjunction with your

furnace to control the operation of the

humidifier.

• Replaces the #58 Aprilaire Automatic

Humidifier Control. Mounts on return

ductwork.

• The control senses indoor RH and outdoor

temperature and automatically adjusts the

operation time of the humidifier to provide

the optimum humidity level in the home.

Locke#

L7154

60

Automatic Digital

Humidifier control

WATER SOLENOID VALVE

Locke#

L7153

RP4040 water solenoid valve