Credit: 405-631-9756
469
www.lockesupplw.comL
|
HVAC
FURNACE CONTROL
Replacement for Lennox
control boards (replaces
all BCC1, BCC2 and
BCC3 circuit boards)
Line Voltage Range: 98-132 VAC @ 60Hz
Cool Blower: 20A @120 VAC
Heat Blower: 20A @120 VAC
Inducer Motor: 5A @120 VAC
Cool Blower ON Delay: 1 second
Cool Blower OFF Delay: 1 second
Heat Blower ON Delay: 45 seconds
Heat Blower OFF Delay: 90, 150, 210, 270
seconds
Locke#
L4920
ICM289 Furnace Control
DSI GAS IGNITION
CONTROL BOARD
• Controls inducer
motors, air cleaner (if
equipped), humidifier
(if equipped), spark
ignitor and the gas
valve
• Microprocessor-based
• Direct Spark Ignition (DSI) control board
• Monitors timing, trial for ignition, system
switches, flame sensing and lockout
• 100% lockout safety feature
• Compatible with LP or Natural Gas
• LED indication for status and fault codes to
aid in troubleshooting
• Replaces: Rheem 62-24140-04
Locke#
L4977
ICM292 DSI Control Board
UNIVERSAL INTEGRATED
FURNACE CONTROL
Built-In EnviraCOM™ Communications
Features universal wiring harnesses that give
you the flexibility you need while in the field
and on the job. Wiring harnesses are included
for simple replacement and installation,
and LED indicators provide system status,
performance and diagnostic information.
Locke#
L3689
S9200U1000
HSI Universal
Integrated Furnace Control
FURNACE & FAN CONTROLS, HEATER & PILOT BURNERS
FURNACE CONTROL
• Low cost, direct replacement board
for
Goodman/Janitrol:
B18099-06,
B18099-08, B18099-10, B18099-13,
B18099-135
UTEC:
1012-933D
Texas Instruments:
41F-5
White-Rodgers:
50T35-730, 50T35-743
• Microprocessor design for precise timing
• Functions with all 24 VAC thermostats
• For 80+ and 90+ applications
• UL recognized
Locke#
L4980
ICM280 Furnace Control
FURNACE CONTROL
• Low cost, direct replacement board for
Carrier CESO11005700/01/02
• Controls gas valve, ignitor, blower motor,
inducer, humidifier and air cleaner
• Microprocessor-based for precise timing
• Functions with all 24 VAC thermostats
• 100% gas shutoff in case of ignition failure
• Twinning compatible with another ICM281
Locke#
L4951
ICM281 Furnace Control
FURNACE CONTROL
• Low cost, direct replacement for Carrier
HK42FZ004
/007/008/009/011/013/016
• Controls gas valve, ignitor, blower motor,
inducer, humidifier and air cleaner
• Microprocessor-based
• 100% gas shutoff in case of ignition failure
• Twinning compatible with another ICM282
• Diagnostic fault codes (blinking LED) to aid
in troubleshooting
Locke#
L4981
ICM282 Furnace Control
FURNACE CONTROL
Replacement for York/
Evcon 7990-319P
control boards
Line Voltage Range: 98 to 132 VAC @ 60Hz
Ignitor: 5A @ 120 VAC
Cool Blower: 10A, 2 HP, 240 VAC
Heat: 5A, 1/2 HP, 250 VAC
Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
Gas Valve: 1A @ 24 VAC
Locke#
L4917
ICM2801 Furnace Control
FURNACE CONTROL
Replacement for Carrier
CES0110074-00/01
control boards
Line Voltage Range: 98-132 VAC @ 60Hz
Cool Blower: 20A, 2 HP, 240 VAC
Heat: 10A, 240 VAC
Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
Inducer Pre-Purge Time: 1 second
Heat Blower On Delay: 45 seconds
Heat Blower Off Delays: 120 or 180 second
Cool Blower On Delay: 1 second
Cool Blower Off Delay: 1 second
Locke#
L4918
ICM2801 Furnace Control
FURNACE CONTROL
Replacement for
Nordyne 903106-Kit
control boards for use
with G3, G4, G5, G6, M2
and M3 furnace modules
Line Voltage Range: 120/240 VAC @ 60 Hz
Ignitor: 5A, 120 VAC
Cool Blower: 10A, 2HP, 240 VAC
Heat: 5A, 1/2 HP, 250 VAC
Inducer Blower: 4A, 120 VAC
Gas Valve: 1A, 24 VAC
Humidifier Motor: 0.5A, 24 VAC
Electronic Air Cleaner: 1A, 120 VAC
Locke#
L4919
ICM2805A Furnace Control