METER SOCKETS

Locke#

P6563

UTRS101BE Ringless, OH/UG,

600v,

125 Amp

8"x12" Meter Socket

P8517

UTRS502BCH

150A

Single Meter

Socket, 4-Terminal, No By-Pass,

Overhead Or Underground Feed

P6564

UTRS202BCH Ringless, OH/UG,

600v,

200 Am

p 8"x14" Meter Socket

P6565

UTRS213CE Ringless, OH/

UG, 600v,

200 Amp

12"x14" Meter

Socket

METER SOCKETS

200 AMP

Locke#

P4022

U4801XL5T9

200A 1Ph

Lever

Bypass Locking Jaw

P4021

U9701-RXL

200A

3 Phase meter

socket with bypass

P4023

U3936R

320A

3 Phase meter

socket

P9091

A7518 2-1/2" Hub For

P4021

P9092

A8110 3" Hub For

P4023

P0280

A9064 Large hub blank for

P4023

P0281

S8324 Large to small hub

adapter plate

METER SOCKET

Locke#

P6478

KU1FS1EMT 1 Phase 400A

(320A Continuous) Meter Socket

P6099

ARP00984 Anti-Inversion clip

for

P6478

P6635

U30 3" Hub for

P6478

P6631

200 Amp Mtr socket, 3" KO

underground entrance

o„ly

,

Mai„ Office: 405-631-9701

836

Fax: 405-631-0585

P

|

ELECTRIC

SPA PAnELS

Enclosures rated at 125A, Lug wire size 6-2/0,

120/240v, NEMA3 R, 10"x7.5"x4"

Locke#

P6690

UG412RMW250 2P 50A GFI

installed and 2 single spaces. UL

GFI Breaker Panel

P6691

UG412RMW260 2P 60A GFI

installed and 2 single spaces. UL

GFI Breaker Panel

DISCOnnECT WITH GFCI

Locke#

P2893

U065P010

60A Non-fused

a/c disconnect with GFCI

P2894

U065NA1010

60 A Non-

automatic disconnect with GFCI

POST OnLY (WITH COVER)

• 9" x 83-1/2" x 4-1/2"

• 3 wire openings (back and sides)

• Earth burial

• Terminal bar assembly with loop

feed lugs standard

• Surface mount units may be field

installed on this post (Not UL listed)

• Latch for padlock provision

• Painted 16 gauge galvanized steel

Locke#

P6455

P6POST Post Only

POWER UNITS

RESIDEnTIAL/

COnSTRUCTIOn, SERVICE

EnTRAnCE

Locke#

P2183

M282CB1

200A Surface

Mount MTRD 14x28"

P6683

R281C1P6H 200A SE Rated

Pedestal with main breaker and 4

blank spaces

TEMPORARY POWER

UnIT

P6622

P6436

P6441

• Rolled edges at cord openings

• Padlockable door

• Wide range of concentric knockouts

• NEMA 3R construction insures complete

protection from the weather.

Locke#

P6622

U666C010 1 2 pole 30A Breaker,

2 single pole 20A breaker,1 30A

10-30R receptacle, 2 GFCI duplex

receptacles

P6436

U038C010 1 2P20 and 2 1P20

breakers, 1 6-20R and 2 5-20R2GFI

Receptacles, rated at 100A,

120/240V

P6441

M038C010 Meter Socket, 1 2P20

and 2 1P20 breakers, 1 6-20R and

2 5-20R2GFI Receptacles, rated at

100A, 120/240V

HUBS

These Hubs Are not I„tercha„geable

Locke#

P6566

1-¼” Hub

P6567

1-½” Hub

P6568

2” Hub

P6569

Closure Plate