EBRT + BT dose

• Dose in elective target volume:

– Homogeneous dose 95%-103% of prescribed dose (PD)

EBRT

BT

Good approximation:

Target:

D90 (total) = PD

(EBRT)

+ D90(BT)

OAR:

D

2cm3

(total) = PD

(EBRT)

+ D

2cm3

(BT)

NOT:

D

2cm3

(total) = D

2cm3 (EBRT)

+ D

2cm3

(BT)