Table of Contents Table of Contents
Previous Page  1152 / 1726 Next Page
Information
Show Menu
Previous Page 1152 / 1726 Next Page
Page Background

64

Planning aim and prescription dose

Planning aim: what you want to obtain

Prescribed dose: what you decide to treat

Structure Dose parameter

Planning aim, Gy Prescribed dose

Gy

Target

Point A

7Gy

6.5Gy

Bladder

ICRU point

≤ 7Gy

6.8 Gy

Rectum ICRU point

≤ 75% of 7Gy

5.3 Gy

Example 2