Note: MC in catalog numbers = Material Codes from this table
Material Selection Codes
Material
Code
Material
Code
Material
Code
Material
Code
304 Stainless
08
A105, Grade II
A2
Hastelloy B
HB
Nickel
NI
309 Stainless
18
Alloy 214
14
Hastelloy C-276
HC
Tantalum
TA
310 Stainless
20
Brass
BR
Incoloy
10
Titanium
TI
316 Stainless
16
Carbon Steel
CS
Inconel 600
09
Teflon
TF
347 Stainless
47
Carpenter 20
CA
Inconel 601
06
Other Materials
available upon
request.
446 Stainless
07
F-11
11
Monel K
MK
A105, Grade I
A1
F-22
22
Monel R
MR
RTD Assembly - Sanitary Clamp Style Stepped Thermowell - T191SFxx:
White FDA Approved Polypropylene Head (NEMA 4X)
SFxx
RTD Thermowell Assembly - Series T191 - PSH
Assembly
Part Number
Ohms
(Ω)
Flange
Insert
Length
(U)
Shank
Dia.
(Q)
Curve
(Alpha)
4E1T191SF24MC02.5PSH
4E1T191SF24MC04.0PSH
4E1T191SF24MC06.0PSH
4E1T191SF24MC07.5PSH
100
Ω
1 1/2”
Size
(Clamp)
2 1/2”
4”
6”
7 1/2”
1/2”
1/2”
1/2”
1/2”
European
(0.00385)
4E1T191SF32MC02.5PSH
4E1T191SF32MC04.0PSH
4E1T191SF32MC06.0PSH
4E1T191SF32MC07.5PSH
100
Ω
2”
(Clamp)
2 1/2”
4”
6”
7 1/2”
1/2”
1/2”
1/2”
1/2”
European
(0.00385)
4E1T191SF40MC02.5PSH
4E1T191SF40MC04.0PSH
4E1T191SF40MC06.0PSH
4E1T191SF40MC07.5PSH
100
Ω
2 1/2”
(Clamp)
2 1/2”
4”
6”
7 1/2”
1/2”
1/2”
1/2”
1/2”
European
(0.00385)
4E1T191SF56MC02.5PSH
4E1T191SF56MC04.0PSH
4E1T191SF56MC06.0PSH
4E1T191SF56MC07.5PSH
100
Ω
European
(0.00385)
3 1/2”
(Clamp)
2 1/2”
4”
6”
7 1/2”
1/2”
1/2”
1/2”
1/2”
4E1T191SF64MC02.5PSH
4E1T191SF64MC04.0PSH
4E1T191SF64MC06.0PSH
4E1T191SF64MC07.5PSH
100
Ω
European
(0.00385)
4”
(Clamp)
2 1/2”
4”
6”
7 1/2”
1/2”
1/2”
1/2”
1/2”
MC = Select Material Code from table on opposite page 316 SS
(“16’) is standard.
Resistance Temperature Detectors (RTDs) - Platinum - Sanitary Flanges
Manufacturing, Engineering and Sales Since 1938
Phone: 617.527.4385 Fax: 617.964.3746 Email:
sales@asrichards.comPage 157
Visit our website at
www.asrichards.comRTDs
WELLS
√
316SS Stepped Thermowell (#4 RMS Finish)
√
100Ώ Resistance
√
316SS 1/4” Dia. European Curve Element
√
Spring Loaded Element
√
White FDA Approved Polypropylene Head (NEMA 4X)
√
Four Wire Lead Configuration
√
Max. Temp. 400°C (752°F) or High Temp. Option 650°C (1202°F)
√
± 0.04% resistance or ±0.1°C Accuracy
√
Sanitary Flange Process Connection
√
316SS Hex Fitting