* Add required thermocouple length. Multiples of 6” (152.4 mm) starting at 12” are in stock.

.

Typical

Application

Protection

Tube

Wire

Gauge

Type K

Alumina

99.8% Aluminum Oxide,

Alumina has a maximum service temperature of

3450°F (1900°C) in both oxidizing and reducing

atmospheres. Alumina is considered to have

better mechanical strength and chemical

resistance than Mullite. Alumina tubes also have

excellent abrasion resistance. Secondary metal

tubes can be added for additional protection from

mechanical damage. Alumina tubes are

considered gas tight so they make excellent

primary protection tubes. All tubes, which are

used in horizontal installations and are at

elevated temperatures, should be supported.

Alumina tube can be used as primary protection

tubes on noble (platinum based) thermocouples.

Alumina tubes have a low silica content so they

will not contaminate platinum thermocouple

elements.

Alumina

Single tube, O.D. 3/8” (9.5 mm)

3/8” NPT steel nipple 1 1/2” long

Bushing, 1/2” x 3/8” NPT

24

24S4-AP06N-*-SH

Alumina

Single tube, O.D. 11/16” (17.5 mm)

1/2” x 3/4” NPT steel fitting

24

24S4-AP11F-*-SH

Alumina

Single tube, O.D. 11/16” (17.5 mm)

3/4” NPT alloy 600 nipple sleeve

Specify sleeve length (

Z

)

24

24S4-AP11N9-Z-*-SH

Mullite Porcelain

Single tube, O.D. 3/8” (9.5 mm)

Plug and Jack

3/8” NPT special steel hex fitting 1 1/2” long

24

24S4-P06HXPJ-RS3-*

Mullite

63.5% Aluminum Oxide,

balance Silicon Dioxide

Mullite has a maximum service temperature of

2900°F (1590°C). It is considered to be better

than Alumina for thermal shock resistance.

Mullite tubes should be used with care, since

they have poor mechanical shock resistance.

Secondary metal tubes can be added for

protection from mechanical damage. Mullite

tubes are considered gas tight at high

temperatures. All tubes which are used in hori-

zontal installations and at elevated temperatures

should be supported. Mullite tubes should not be

used for primary protection tubes on noble metal

(platinum based) thermocouples if the

temperature will exceed 2200°F (1200°C). Above

these temperatures the silica in the Mullite can

contaminate the platinum element if there is not

enough good air circulation inside the tube.

Mullite Porcelain

Single tube, O.D. 3/8” (9.5 mm)

1/2” NPT alloy 600 nipple sleeve

Specify sleeve length (

Z

)

24

24S4-P06N9-Z-*-SH

Mullite Porcelain

Single tube, O.D. 11/16” (17.5 mm)

1/2” x 3/4” NPT steel fitting

24

24S4-P11F-*-SH

Mullite Porcelain

Single tube, O.D. 11/16” (17.5 mm)

3/4” NPT steel nipple 2 1/2” long.

24

24S4-P11N-*-SH

2

3

4

1

6

5

7

Easy to Order -

1 - State quantity

2 - Specify the part number

(ours or competitive)

3 - Specify the length * Multiples of 6” (152.4 mm)

starting at 12” are stocked.

4 - Add letters for mounting attachments

5 - For Double Element Assembly add “D” to the

part number (

24D4D-P11F-12-SH

)

Example:

The part number describes the thermocouple giving the

gauge, type of wire, construction, tube length and mounting device, if any. The part

number

24S4-P11F-24-SH

signifies A 24 gauge, Type S complete assembly, 11/16”

OD Mullite tube, 24” long, a 1/2” x 3/4” steel fitting, and a Standard Head (

SH

). Other

combinations of thermocouples and tubes can be specified depending on your applica-

tion.

!

Note:

If you would like to order a Type B, or Type R assembly, just substitute

the S with an B, or R in the part numbers listed on this page.