Post-Op Endometrial RT Contouring

CTV-T

= Upper 3cm of vaginal vault and parametrium.

PTV-T

= CTV + 12mm in all directions except inferiorly and

laterally where 7mm is sufficient.

CTV-N

= (as per Taylor guidelines) includes obturator nodes,

external iliac lymph nodes, internal iliac lymph nodes.

The common iliac nodes may be included for node

positive patients (Stage IIIC1). The para-aortic nodes

may be included for those with Stage IIIC2 tumours.

PTV-N

= CTV + 7mm margin.

PTV final = PTV-T + PTV-N