5/80

All stocked articles available within 24 hours by UPS Express.

All prices excluding VAT per piece (if not stated otherwise).

5

Hand Tools

Design:

Display and operation via colour LCD touch screen with help function and connection

diagrams, battery supported upon failure of the mains voltage. Function test with display of

voltage, current, active and apparent power. Automatic and manual testing with pass/fail

indicator and audible warning when test fails. Complete test item database stored on SD card,

free firmware update via SD card/USB stick. With 3 USB ports, external keyboard, RS-232

interface for barcode scanners, printer and SD card slot.

Application:

For

safety inspections of electrical equipment and work equipment in

accordance with VDE 0701-0702, DGUV Rule 3,

Ind. Safety Ord. and

electrical medical

equipment in accordance with DIN VDE 0751-1

(DIN EN 62353), Type B, BF, CF, hospital/

nursing home beds.

Scope of delivery:

Tester in waterproof and dustproof (IP67), break-proof case, test cable with

alligator clip, appliance cable, 2 GB SD card (for about 100000 specimen), stylus, software

BENNING PC-Win ST 750, barcode scanners, barcode labels (1000 pieces), Inspection stickers

(300 pieces).

Order No.

0751

Model

ST 750 A SET

5561

1849.00

Protective conductor resistance

1–20 Ohm

Test current

± 200 mA DC, 10 A AC

Insulation resistance

0.1 MOhm–100 MOhm

Test voltage

50 V–500 V DC

Protective earth/contact current

via differential measurement/

direct measurement/alternate

eliminating current procedure

0.05 mA–25 mA

Device leakage current and

leakage current from appli-

cation part for ME devices

0.05 mA–25 mA

Voltage/current

1 V–360 V/0.1 A–16 A

Active/apparent output

20 W–4000 W

Interface

3 x USB, 1 x RS232

Display

Colour LCD touch screen

(511)

SET ST 750 A device tester

Design:

Housing made of impact resistant plastic, graphic display with back light, help function

with connection diagram, measured value memory about 4 levels (object, block, fuse, measuring

point), upload of system structures, download of measured values, integrated real time clock

(measured value with date/time). Help function with connection diagram, online voltage monitor,

test procedure with good/bad display, bi-directional interfaces (USB/RS 232), test report

according to ZVEH.

Application:

For

safety inspections of electrical installations according to DIN VDE 0100-600

and DIN VDE 0105-100,

e.g. Testing of FI/RCD circuit breaker standard and delayed (S)

Type AC, A, F, B, B+ with AUTO-test, contact voltage, triggering time and triggering current

(ramp).

Scope of delivery:

Tester, PC software, USB cable, RS232 cable, switchable Commander

probe, test cable with safety plug, 3-wire test lead with 1.5 m length, 3 probes, 3 alligator clips,

battery charger with 6 NiMH AA batteries and case.

Order No.

0130

Model

IT 130

5586

1299.80

Low resistance

0.01 Ohm–2 kOhm

Insulation resistance

10 kOhm–1000 MOhm

Line impedance (L-N/L)

0.01 Ohm–10 kOhm

Loop impedance (L-PE)

0.01 Ohm–10 kOhm

Short-circuit current

0.01 A–200 kA

Rotary field

yes

Voltage

1 V–550 V

Frequency

0 Hz–500 Hz

Measured data storage

1800

Measuring procedure

TRUE RMS

Dimensions (L x W x H)/weight

103 x 230 x 115 mm/1.17 kg

Batteries

6 x NiMH AA batteries 1.5 V

(511)

Installation tester TRUE RMS IT 130

Test and measuring devices

950