Document realized with version :
CURRENTREV.
forbidden.
APPROVEDBY.
CLIENT.
DRAWNBY.
CHECKEDBY.
DESCRIPTION.
Petro-Chem, Process & Food Industries Across theUK.
CHKD.
Flotech Performance Systems Ltd
REV.
Reproduction, use or disclosure to thirdpartieswithoutexpressauthority isstrictly
DRAWINGTITLE.
We reserve all rights in this documentand the informationcontained therein.
Fareham, Hampshire
Unit 2, Salterns Ind. Est.
EMAIL:
sales@flotechps.comSpecialist Multi-Discipline Engineering Services to the
PROJECTNAME.
Salterns Lane
N.T.S.
WEB:
www.flotechps.comTEL: +44 (0) 1329 284145
PROJECT#.
DRAWING#.
CLIENTAPPROVEDBY.
SCALE.
STATUS.
SIZE.
©FLOTECH PERFORMANCE SYSTEMS LTD 2015
DATE.
ORDER#.
DATE
of
SHEETS.
Electrical, Instrumentation & Mechanical Engineers.
CUSTOMERDRAWINGNUMBER
BY.
APP.
NOTES
PO16 0SU
1
2
3
4
5
10
9
8
7
6
5
4
3
2
1
SOLIDWORKS Electrical
2016.0.3.12
11
12
13
14
6
7
8
9
Vivergo Fuels Project
FPS100639
A
6
AsBuilt
SKID B
Control Panel Power Distribution
FPS100639
15/07/2016
INJECTION, BLENDING & PUMPING SYSTEM
17
A
K E
R H MD
06
K E
15/07/2016
K
19
A09-3-
6Motor Contactor Coil
PUMP 1
1/L1
2/T1
3/L2
4/T2
5/L3
6/T3
LC1D09BL
SKID B Control Panel 9-CP62-04-51-2
F1
1A
Pump Control
F2
1A
PLC O/P
PLC Supply
F3
1A
Safety Relay
TO: 08-2
TO: 08-1
SUPPLY 1
MTR 1
F4
1A
Pressure Switch
F5
1A
Level Switch
F6
1A
Indication
Transfer Valve
TO: 08-2
TO: 07-41X1
1X1
I I IQ1
1 - 1.
6AMotor 0.55k
WThermal
O/L1/L1
2/T1
3/L2
4/T2
5/L3
6/T3
GV2ME06
Q3
C
10A
1
2
3
4
5
6
GVAD0110
F7
1A
TO: 07-4SUPPLY From Isolator
SUPPLY TO SKID 1 ADDITIVE PUMP 1
PUMP CONTROL AND PLC PERMISSIVE
PLC SUPPLY & PLC O/Ps
SAFETY RELAY SUPPLY
E
E
SOME SCREENS ONLY SHOWN ON SINGLE CORES FOR CLARITY
L3-0
L2-0
L1-0
105
104
101
105
C04-B\Bk
101
104
C01-B\Bk
101
101
101
103
101
102
201
SCN
L3-0
L2-0
SCN
0VDC
0VDC
0VDC
0VDC
C02-B\Core 3
0VDC
0VDC
E
P01-B\Core 4
L3-0
P01-B\Core 3
L2-0
P01-B\Core 2
L1-0
P01-B\Core 1
101
E
L1-1
L1-0
L3-1
L2-1
I I IQ2
1 - 1.
6AMotor 0.55
kWThermal
O/L1/L1
2/T1
3/L2
4/T2
5/L3
6/T3
GV2ME06
K
29
A09-5-
6Motor Contactor Coil
PUMP 2
1/L1
2/T1
3/L2
4/T2
5/L3
6/T3
LC1D09BL
L1-0
L2-0
L3-0
L2-3
L3-3
L1-3
E
P03-B\Core 4
L3-4
P03-B\Core 3
L2-4
P03-B\Core 2
L1-4
P03-B\Core 1
95
96
09-5-5
53
54
08-2-4
95
96
09-3-5
53
54
08-1-4
SUPPLY TO SKID 1 ADDITIVE PUMP 2
H1
Power ON
WHITE LED
X1
X2
107
0VDC
TO: 08-7MTR 2
L3-4
L2-4
L1-4
FROM: 05-3
FROM: 05-3
FROM: 05-3
106
C03-B\Bk
1X1
106
C03-B\Bu
E
SCN
TO: 07-4 TO: 07-4 TO: 07-4136
C02-B\Core 1
136
FROM: 09-4 TO: 07-4TO TRANSFER VALVE
F8
1A
Slow Blow
107
101
106
E
C02-B\Core 2
E
E
1X1
TO: 07-4400VAC
24VDC
T1
CP-T 24/5.0
1SVR 427 054 R0000
5A
E
L1 L2 L3
L+ L+ L- L-
13 14
101
0VDC
L1-5
L3-5
E
L2-5
SKID B/C/D/E AS MARKED WITH B/C/D/E
SKID A AS MARKED
GVAD0110
FROM: 05-3
E
E
E
E
E
E
P02-B\Core 4
E
E
E
ALL EARTH CORES TO HAVE Gn/Ye SLEEVING AS REQUIRED
TO: 05-6 TO: 05-7 TO: 05-7 TO: 05-7L3-0
L2-0
L1-0
L1-2
L2-2
L3-3
E
TO: 05-5 TO: 05-5 TO: 05-5 TO: 05-6L3-3
P02-B\Core 3
L2-2
P02-B\Core 2
L1-2
P02-B\Core 1
mm² 1361.5
Brown
mm²
0VDC
1.5
Grey
mm² E1.5
Black
mm² 1060.75
Bluemm²
106
0.75
Black
mm² 1050.75
Black
mm² 1040.75
Black