16

i) Safety function will not work at all

Counter-measures:

Log forces no matter how temporary, with system to ensure removed

Only allow self-revealing forces

Modify test procedures – e.g. to inspect communication blocks, or test

SIFs in appropriate order (test the SIF that is required to be forced last)

Design for testing and operation, avoiding the need for forces. E.g.

prohibiting maintenance override may necessitate a force to re-start the

plant.

Competence, auditing, awareness and commissioning supervision of

logic solver vendor.

Neil Wakeling, August 2014