Physics Bucharest 2017

6/3/2017

Cost function for biological constraints

Generalized Equivalent Uniform Dose (gEUD)

Niemierko 1997,1999 Med.Phys

a = 1 a --> -∞ a --> +∞

EUD = Dmean EUD --> Dmin EUD --> Dmax

EUD can be optimised to “equal”, (gEUD-D 0 ), “maximum” or “minimum”

gEUD : phenomenological description of the biological response to the radiation

In principle applicable to target volumes and OARs

23

Simple gEUD for 3 structures

Differential and cumulative DVH

100

Target OARs OARp

90

80

70

60

50

gEUD value

40

Min dose (55Gy,1Gy,1Gy) seen at low a

30

20

70,000

10

0

60,000

dose

10

20

30

40

50

60

50,000

40,000

Max dose (68Gy, 47Gy, 65Gy) at high a

Target OARs OARp

30,000

EUD

20,000

10,000

,000

-50

-10

1

10

50

24

a value in EUD formular

Made with