Research Masterclass in Radiotherapy Physics 2017
Additional problem: Range uncertainty
Small uncertainties in density may result in larger dose uncertainties as compared to MV photons
Oliver Jäkel
Medical Physics
Page 11
Initial Planning CT GTV 115 cc 5 weeks later GTV 39 cc Lung Tumor shrinkage during p-therapy
Beam stops at distal edge Beam overshoot
Courtesy of S. Mori, G. Chen, MGH, Boston
Oliver Jäkel Need for replanning and adaption during course of RT Medical Physics
Page 12
Made with FlippingBook Annual report