GE Products BuyLog Smart Catalog
Uninterruptible Power Supplies Energy Connections SG Series 225-300 kVA Three-Phase SG Software and Connectivity Products
Section 20
SG Software/Monitoring Description
Product Number
Advanced SNMP/Web interface card, RTU 485
1024921
Remote Status Panel (includes APS)
17442
Customer Interface Card (CIC) - six programmable relay contacts
1020010
GE eBoost TM (Multi-Mode) Factory-Installed Software
Description
Product Number
SG Series, 225kVA SG Series, 300kVA
UPS225EBSFTWR UPS300EBSFTWR
Internal Maintenance Bypass for SG UPS Module
Description
Product Number
225kVA, Factory Installed 300kVA, Factory Installed
UPS225INTMBPOPT UPS300INTMBPOPT
Dual Input for SG UPS Module
Product Number
Description
UPS225DUALACOPT UPS300DUALACOPT
225kVA, Factory Installed 300kVA, Factory Installed
High Fault Rating for SG UPS Module
Description
Product Number
UPS22565KAIC UPS30065KAIC
SG 225kVA UPS rated 65k AIC, Factory Installed SG 300kVA UPS rated 65k AIC, Factory Installed
UPS Input Transformers (NEMA 1 non-matching enclosure, Aluminum, K0)
UPS kVA Rating, Voltage (Input-Output)
Weight (lbs)
Dimensions W x D x H (in)
Xfmr kVA
Product Number
SG 225/300kVA (208V - 480/277V) DOE2016 Compliant SG 225/300kVA (480V - 480/277V) DOE2016 Compliant
3300
49 x 42 x 64
500
SG3A0500BK
2950
49 x 42 x 64
500
SG3A0500KK
UPS Output Transformers (NEMA 1 non-matching enclosure, Aluminum, K0)
UPS kVA Rating, Voltage (Input-Output)
Weight (lbs)
Dimensions W x D x H (in)
Xfmr kVA
Product Number
SG 225/300kVA , (480V - 208/120V) DOE2016 Compliant
2750
49 x 42 X 64
500
SG3A0500KB
Battery System Temperature Sensor (Only 1 per UPS System)
Description
Product Number
Series SG UPS, 5 meter long sensor Series SG UPS, 15 meter long sensor Series SG UPS, 20 meter long sensor Series SG UPS, 30 meter long sensor Series SG UPS, 60 meter long sensor
1016076 1016081 1016088 1016089 1016197
1 The SG Series UPS comes with one Customer Interface Card (CIC) pre-installed in the card cage. The card cage has one open slot for optional cards. This slot can hold either an additional Customer Interface Card OR an SNMP Interface Card, but not both. 2 The Remote Status Panel uses the Customer Interface Card that is supplied with the system.
A second Customer Interface Card is required If relay contacts are required for other purposes (such as interface to an External Bypass Panel). 3 Systems using the optional Customer Interface Card will need to use the External SNMP Interface Box, if SNMP connectivity is required.
Rev. 1/19 Data subject to change without notice
go.abb/industrial
GE Products BuyLog
20-49
Made with FlippingBook - Online magazine maker