GE Products BuyLog Smart Catalog
Uninterruptible Power Supplies Energy Connections TLE Series UPS 225 - 1000 kVA External Maintenance Bypass Cabinets
Section 20
Series TLE UPS - 3 Breaker Matching, Free Standing Maintenance Bypass Cabinet (MBC)
TLE UPS kVA
UIB CB (Trip Rating) 400AT (80%) 450AT (80%) 600AT (100%) 700AT (100%) 1200AT (100%) 1600AT (100%)
MIB & MBB CB (Trip Rating)
kAIC Rating @ 480VAC
Width (in)
Depth (in)
Height (in)
Weight (lbs)
Product Number
75 75 75 75 75 75
310 360 360 630 710
MBC224-35400T-L600 MBC254-40450T-L600 MBC404-60600T-L600 MBC504-80700T-L600 MBC754-A0A20T-L600 MBCA04-A6A60T-L600
225 250 400 500 750
350AT (80%) 400AT (80%) 600AT (80%) 800AT (80%)
65kAIC 65kAIC 65kAIC 65kAIC 65kAIC 65kAIC
30.0 30.0 30.0 36.0 36.0 92.0
32.8 32.8 32.8 32.8 32.8 32.8
1000AT (100%) 1600AT (100%)
1000
1200
Notes on TLE Matching MBC: 1. Cabinets are matching height, depth, and black in color same as UPS Module 2. Baseline configuration is 3-Breaker Type, 480/277V 3ph 4w + gnd. Neutral not used in 3w UPS applications. 3. Base MBC includes 3-breaker with mechanical Kirk Key configuration.
For 3-breaker MBC with electric interlock (with SKRU) change, the Base MBC, digit #15 to "K", example: MBC224-35400T-K600 For 2-breaker MBC with mechanical Kirk Key change, the Base MBC, digit #10 & #11 to "00", example: MBC224-35000T-L600 For 2-breaker MBC with electric interlock (with SKRU) change, the Base MBC, digit #10 & #11 to "00" and digit # 15 to "K", example: MBC224-35000T-K600
4. Cabinet conduit access via top, bottom, and sides via knockouts. 5. Warranty is 1 year. Leadtime is 4-8 weeks (typical) via sourced supplier.
Series TLE UPS - 3 Breaker Non-Matching, Free Standing Maintenance Bypass Switchboard (MBS-UL891)
Product Number
Height (in)
Weight (lbs)
Width (in)
Depth (in)
MIB & MBB CB (Trip Rating)
kAIC Rating @ 480VAC
TLE UPS kVA
UIB CB (Trip Rating) 700AT (100%) 700AT (100%) 700AT (100%) 1200AT (100%) 1200AT (100%() 1200AT (100%() 1600AT (100%) 1600AT (100%)
800AT (80%) 800AT (80%) 800AT (80%)
50kAIC 65kAIC 100kAIC 50kAIC 65kAIC 100kAIC 65kAIC 100kAIC
45 45 45 45 45 45 60 60
30 30 30 30 30 30 35 35
90 90 90 90 90 90 90 90
760 760 760 760 760 760
MBS504-80700T-K500 MBS504-80700T-K600 MBS504-80700T-KA00 MBS754-A0A20T-K500 MBS754-A0A20T-K600 MBS754-A0A20T-KA00 MBSA04-A6A60T-K600 MBSA04-A6A60T-KA00
500 500 500 750 750 750
1000AT (100%) 1000AT (100%) 1000AT (100%) 1600AT (100%) 1600AT (100%)
1000 1000
1376 1376
Notes on TLE Non-Matching MBS cabinets: 1. Cabinets are ANSI grey (switchboard) color 2. Baseline configuration is 3-Breaker Type, 480/277V 3ph 4w + gnd. Neutral not used in 3w UPS applications. 3. Circuit Breaker interlock system is Kirk Key electric interlock (w/SKRU) 4. Cabinet conduit access via top and bottom via knockouts. 5. Warranty is 1 year. Leadtime is 4-8 weeks (typical) via GE factory.
Series TLE UPS - 3 Breaker Non-Matching, Wall Mounted Maintenance Bypass Panel (MBP) - Style A
TLE UPS kVA
UIB CB (Trip Rating) 400AT (80%) 400AT (80%) 450AT (80%) 450AT (80%) 700AT (80%) 700AT (80%) 1000AT (80%) 1000AT (80%)
MIB & MBB CB (Trip Rating)
kAIC Rating @ 480VAC
Width (in)
Depth (in)
Height (in)
Weight (lbs)
Product Number
225 225 250 250 400 400 500 500
350AT (80%) 350AT (80%) 400AT (80%) 400AT (80%) 600AT (80%) 600AT (80%) 800AT (80%) 800AT (80%)
35kAIC 35kAIC 35kAIC 35kAIC 35kAIC 35kAIC 50kAIC 50kAIC
40 40 40 40 40 40 40 40
14 14 14 14 14 14 14 14
91 91 91 91 91 91 91 91
557 557 557 557 557 557 557 557
GT20350-10400-A1S GT20350-10400-A2S GT20400-10450-A1S GT20400-10450-A2S GT20600-10700-A1S GT20600-10700-A2S GT20800-11000-A1S GT20800-11000-A2S
Notes on TLE Non-Matching, Wall-mounted Maintenance Bypass Panelboard (MBP) 1. Panelboards are ANSI grey color 2. Baseline configuration is 3-Breaker Type, 480/277V 3ph 4w + gnd. Neutral not used in 3w UPS applications. 3. Circuit Breaker interlock systems are Mechanical Kirk Key (KK) and electric interlock (w/SKRU) 4. Cabinet conduit access via top and bottom via knockouts. 5. Warranty is 1 year. Leadtime is 4-8 weeks (typical) via Source Suppliers
Rev. 1/19 Data subject to change without notice