GE Products BuyLog Smart Catalog

Uninterruptible Power Supplies Energy Connections TLE Series UPS 225 - 1000 kVA External Maintenance Bypass Cabinets

Section 20

Series TLE UPS - 3 breaker Non-Matching, Wall Mount Maintenance Bypass Panel (MBP) - Style B

TLE UPS kVA

UIB CB (Trip Rating) 400AT (80%) 450AT (80%) 600AT (100%) 700AT (100%) 1200AT (100%)

MIB & MBB CB (Trip Rating)

kAIC Rating @ 480VAC

Width (in)

Depth (in)

Height (in)

Weight (lbs.)

Product Number

125 140 140 165 165

MBP224-35400T-L600 MBP254-40450T-L600 MBP404-60600T-L600 MBP504-80700T-L600 MBP754-A0A20T-L600

30 36 36 36 36

11 14 14 14 14

42 48 48 48 48

225 250 400 500 750

350AT (80%) 400AT (80%) 600AT (80%) 800AT (80%)

65kAIC 65kAIC 65kAIC 65kAIC 65kAIC

1000AT (100%)

Notes on TLE Wallmount MBP: 1. Cabinets are black in color. 2. Baseline configuration is 3-Breaker Type, 480/277V 3ph 4w + gnd. Neutral not used in 3w UPS applications. 3. Base MBP includes 3-breaker with mechanical Kirk Key configuration.

For 3-breaker MBP with electric interlock (with SKRU) change, the Base MBP, digit #15 to "K", example: MBC224-354000-K600 For 2-breaker MBP with mechanical Kirk Key change, the Base MBP, digit #10 & #11 to "00", example: MBC224-350000-L600 For 2-breaker MBP with electric interlock (with SKRU) change, the Base MBP, digit #10 & #11 to "00" and digit # 15 to "K", example: MBC224-350000-K600 4. Cabinet conduit access via top and bottom via knockouts. 5. Warranty is 1 year. Leadtime is 3-5 weeks (typical) via sourced supplier.

Series TLE UPS - 4x2 Combo, 3 Breaker Maintenance Bypass Cabinet (MBC) w/Output Isolation Transformer

UIB CB (Trip Rating)

MIB & MBB CB (Trip Rating)

kAIC Rating @ 480VAC

Weight (lbs.)

Product Number

TLE UPS kVA

Width (in)

Depth (in)

Height (in)

225 225 250 250

400AT (80%) 400AT (80%) 450AT (80%) 450AT (80%)

350AT (80%) 350AT (80%) 400AT (80%) 400AT (80%)

35kAIC 65kAIC 35kAIC 65kAIC

54 54 54 54

33 33 34 34

75 75 75 75

2200 2200 2500 2500

MBC224-35400T-L322 MBC224-35400T-L622 MBC254-40450T-L325 MBC254-40450T-L625

Notes on TLE 4x2 combo MBC: 1. Cabinets are matching depth, height, and black color same as UPS Module 2. Baseline configuration is 3-Breaker Type, 480/277V 3ph 4w + gnd. K13 DOE2016 Compliant copper transformer, 480V-208/120V 3. Base 4x2 Combo MBC includes 3-breaker with mechanical Kirk Key configuration.

For 4x2 Combo 3-breaker MBC with electric interlock (with SKRU) change, the Base MBC, digit #15 to "K", example: MBC224-35400T-K622 For 4x2 Combo 2-breaker MBC with mechanical Kirk Key change, the Base MBC, digit #10 & #11 to "00", example: MBC224-35000T-L622 For 4x2 Combo 2-breaker MBC with electric interlock (with SKRU) change, the Base MBC, digit #10 & #11 to "00" and digit # 15 to "K", example: MBC224-35000T-K622 4. Cabinet conduit access top and bottom via knockouts. 5. Warranty is 1 year. Leadtime is 6-8 weeks (typical) via sourced supplier.

Rev. 1/19 Data subject to change without notice

go.abb/industrial

GE Products BuyLog

20-61

Made with FlippingBook - Online magazine maker