GE Products BuyLog Smart Catalog
Uninterruptible Power Supplies Energy Connections TLE Series UPS 225 - 1000 kVA External Maintenance Bypass Cabinets
Section 20
Series TLE UPS - 3 breaker Non-Matching, Wall Mount Maintenance Bypass Panel (MBP) - Style B
TLE UPS kVA
UIB CB (Trip Rating) 400AT (80%) 450AT (80%) 600AT (100%) 700AT (100%) 1200AT (100%)
MIB & MBB CB (Trip Rating)
kAIC Rating @ 480VAC
Width (in)
Depth (in)
Height (in)
Weight (lbs.)
Product Number
125 140 140 165 165
MBP224-35400T-L600 MBP254-40450T-L600 MBP404-60600T-L600 MBP504-80700T-L600 MBP754-A0A20T-L600
30 36 36 36 36
11 14 14 14 14
42 48 48 48 48
225 250 400 500 750
350AT (80%) 400AT (80%) 600AT (80%) 800AT (80%)
65kAIC 65kAIC 65kAIC 65kAIC 65kAIC
1000AT (100%)
Notes on TLE Wallmount MBP: 1. Cabinets are black in color. 2. Baseline configuration is 3-Breaker Type, 480/277V 3ph 4w + gnd. Neutral not used in 3w UPS applications. 3. Base MBP includes 3-breaker with mechanical Kirk Key configuration.
For 3-breaker MBP with electric interlock (with SKRU) change, the Base MBP, digit #15 to "K", example: MBC224-354000-K600 For 2-breaker MBP with mechanical Kirk Key change, the Base MBP, digit #10 & #11 to "00", example: MBC224-350000-L600 For 2-breaker MBP with electric interlock (with SKRU) change, the Base MBP, digit #10 & #11 to "00" and digit # 15 to "K", example: MBC224-350000-K600 4. Cabinet conduit access via top and bottom via knockouts. 5. Warranty is 1 year. Leadtime is 3-5 weeks (typical) via sourced supplier.
Series TLE UPS - 4x2 Combo, 3 Breaker Maintenance Bypass Cabinet (MBC) w/Output Isolation Transformer
UIB CB (Trip Rating)
MIB & MBB CB (Trip Rating)
kAIC Rating @ 480VAC
Weight (lbs.)
Product Number
TLE UPS kVA
Width (in)
Depth (in)
Height (in)
225 225 250 250
400AT (80%) 400AT (80%) 450AT (80%) 450AT (80%)
350AT (80%) 350AT (80%) 400AT (80%) 400AT (80%)
35kAIC 65kAIC 35kAIC 65kAIC
54 54 54 54
33 33 34 34
75 75 75 75
2200 2200 2500 2500
MBC224-35400T-L322 MBC224-35400T-L622 MBC254-40450T-L325 MBC254-40450T-L625
Notes on TLE 4x2 combo MBC: 1. Cabinets are matching depth, height, and black color same as UPS Module 2. Baseline configuration is 3-Breaker Type, 480/277V 3ph 4w + gnd. K13 DOE2016 Compliant copper transformer, 480V-208/120V 3. Base 4x2 Combo MBC includes 3-breaker with mechanical Kirk Key configuration.
For 4x2 Combo 3-breaker MBC with electric interlock (with SKRU) change, the Base MBC, digit #15 to "K", example: MBC224-35400T-K622 For 4x2 Combo 2-breaker MBC with mechanical Kirk Key change, the Base MBC, digit #10 & #11 to "00", example: MBC224-35000T-L622 For 4x2 Combo 2-breaker MBC with electric interlock (with SKRU) change, the Base MBC, digit #10 & #11 to "00" and digit # 15 to "K", example: MBC224-35000T-K622 4. Cabinet conduit access top and bottom via knockouts. 5. Warranty is 1 year. Leadtime is 6-8 weeks (typical) via sourced supplier.
Rev. 1/19 Data subject to change without notice