ABLOY
ABLOY PRODUCT AND PACKAGES
ABLOY
!J Package IE
t
(1 •
u.
Standard door Read in, freeegress-complieswith EN179 1. EL560 solenoid lock 2. CY326 single cylinder - DIN Europrofile 3. EA280 concealed door loop 4. 60-0319-SSS handle set 5. DC240 door closer (optional) 6. 3-19/042 PZ+BL-SSS alternative
ORDERING CODES ABLOY-EL560-55-PACK1E ABLOY-EL560-60-PACK1E ABLOY-EL560-65-PACK1E ABLOY-EL560-80-PACK1E ABLOY-EL560-100-PACK1E
Wood or metal door applications with handle operation, inside handle always operates and the outside handle is controlled and activated on signal from access control system. Key override at all times from outside. Technical Specification: Operating voltage: 12 Voc to24 Voe stabilised (+15%-10%). Current draw:12 Voc350 mA max 24 Voc250 mAmax. Backsets available: Standard65 mm,55 mm,60 mm,80 mm,100 mm. Monitoring: RQEon inside handle, bolt position, door position, cylinder operation.
Standards: EN179 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
ABLOY
!l Package IME Multipoint
J.. I I
t
0.
Standard door
Multipoint - Read in, free egress - complies with EN179 1. EL566 multipoint solenoid lock 2. CY326 single cylinder - DIN Europrofile 3. EA280 concealed door loop 4. 60-0319-SSS handle set 5. DC240door closer (optional) 6. 3-19/042 PZ+BL-SSS (alternative) Wood or metal door applications with handle operation, inside handle always operates and the outside handle is controlled and activated on signal from access control system. Key override at all times from outside. Technical Specification: Operating vol tage: 12 Voe to24 Voe stabilised ( + 15%-10%). Current draw: 12 Voc350 mA max 24 Voc250 mA max. Backsets available: Standard 65 mm, 55 mm, 60 mm. Monitoring: RQE on inside handle, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-EL566-55-PACK1ME ABLOY-EL566-60-PACK1ME ABLOY-EL566-65-PACK1ME
Standards: EN179 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
II
ABLOY
E! Package IMP Escape (EN1125)
J. I
I
Standard door
Multipoint - Read in, free egress - complies with EN1125 1. EL566 solenoid lock 2. CY326 single cylinder - DIN Europrofile 3. EA280 concealed door loop 4. PBE011-EL560 ABLOY panic bar with 1/2 handle set 5. DC240 door closer (optional) Wood or metal door applications with handle operation, inside panic bar always operates and the outside handle is controlled and activated on signal from access control system. Key override at all times from outside. Technical Specification: Operating voltage: 12 Voc to 24 Voc stabilised ( + 15%-10%). Current draw: 12 Voe 350 mA max 24 Voe 250 mA max. Backsets available: Standard 65 mm, 55 mm, 60 mm. Monitoring: RQE on panic bar, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-EL566-55-PACK1MP ABLOY-EL566-60-PACK1MP ABLOY-EL566-65-PACK1MP
Standards: EN1125 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
ABLOY
E! Package IP
Escape (EN1125)
Standard door
ORDERING CODES ABLOY-EL560-55-PACK1P ABLOY-EL560-60-PACK1P ABLOY-EL560-65-PACK1P ABLOY-EL560-80-PACK1P ABLOY-EL560-100-PACK1P
Read in, free egress - complies with EN1125 1. EL560 solenoid lock 2. CY326 single cylinder - DIN Europrofile 3. EA280 concealed door loop 4. PBE011-EL560 ABLOY panic bar with 1/2 handle set 5. DC240 door closer (optional)
Wood or metal door applications with handle operation, inside panic bar always operates and the outside handle is controlled and activated on signal from access control system. Key override at all times from outside.
Technical Specification: Operating voltage: 12 Voe to 24 V oc stabilised (+15%-10%). Current draw: 12 Voe 350mAmax 24 V oc 250 mA max.
Backsets available: Standard 65mm, 55mm, 60mm, 80mm, 100mm. Monitoring: RQE on panic bar, bolt position, door position, cylinder operation.
Standards: EN1125when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
ORDERING CODES ABLOY-EL56 1 -55-PACK2 ABLOY-EL56 1 -60-PACK2 ABLOY-EL56 1 -65-PACK2
ORDERING CODES ABLOY-EL56 1 -55-PACK2 ABLOY-EL56 1 -60-PACK2 ABLOY-EL56 1 -65-PACK2
ABLOY
Package2M Multipoint
0 0
Standard door
Multipoint - Read in, read out 1. EL567 solenoid lock 2. EA280 concealed door loop 60-0319-SSS handle set DC240 door closer (optional)
ORDERING CODES ABLOY-EL56 7 -55-PACK2M ABLOY-EL56 7 -60-PACK2M ABLOY-EL56 7 -65-PACK2M
CY327 double cylinder - DIN Europrofile
3. 4. 5. 6.
3-19/042 PZ+PZ-SSS (alternative)
Wood or metal door applications with handle operation, both handles controlled and activated on signal from access control system. Key override at all times from both sides. Technical Specification: Operating voltage: 12 Voe to 24 Voe stabilised ( + 15%-10%). Current draw: 12 Voc350 mAmax 24 Voe250mAmax. Backsets available: Standard 65 mm, 55 mm, 60 mm. Monitoring: RQE on inside handle, bolt position, door position, cylinder operation.
Standards: EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
ORDERING CODES ABLOY-EL460-30-PACK3E ABLOY-EL 4 60-35-PACK3E ABLOY-EL 4 60-40-PACK3E ABLOY-EL 4 60-45-PACK3E
ABLOY
1J Package 3ME Multipoint
r: :
I'
J
Narrow stile door
Multipoint - Read in, free egress - complies with EN179 1. EL466 solenoid Lock 2. CY326 single cylinder - DIN Europrofile 3. □ LB door Loop 4. 60-0819-SSS handle set to suite the EL460 5. DC240 door closer (optional) 6. 3192750/PZ+BL (alternative) Narrow stile door applications with handle operation, inside handle always operates and the outside handle is controlled and activated on signal from access control system. Key override at all times from outside. Technical Specification: Operating voltage: 12 V DC to 24 V DC stabilised (+15%-10%). Current draw: 12 V Dc350 mA max 24 V Dc250 mA max. Backsets available: 30 mm, 35 mm, 40 mm, 45 mm. Monitoring: RQE on inside handle, bolt position, door position, cylinder operation. O R D ER I N G COD E S ABLOY-EL466-30-PACK3ME ABLOY-EL466-35-PACK3ME ABLOY-EL466-40-PACK3ME ABLOY-EL466-45-PACK3ME
Standards: EN179when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
ABLOY
E! Package 3MP Escape (EN1125)
a
u
Narrow stile door
Multipoint- Read in, free egress- complies with EN1125 1. EL466 solenoid lock 2. CY326 singlecylinder - DIN Europrofile 3. D LB door loop 4. PBE011-EL460 ABLOY panic bar with 1/2 handle set 5. DC240 door closer (optional) Narrow stile door applications with handle operation, inside panic bar always operates and the outside handle is controlled and activated on signal from access control system. Key override at all times from outside. Technical Specification: Operating voltage: 12Vocto 24Vocstabilised (+15%-10%). Currentdraw: 12Voc350mAmax 24Voc250mAmax. Backsets available: 30mm, 35mm, 40mm, 45mm. Monitoring: RQE on panic bar, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-EL466-30-PACK3MP ABLOY-EL466-35-PACK3MP ABLOY-EL466-40-PACK3MP ABLOY-EL466-45-PACK3MP
Standards: EN1125when used with correct furniture EN1634-l EN61000-6-1 EN1303 (cylinder) EN14846
ABLOY
E! Package 3P
Escape (EN1125)
D
u
Narrow stile door
Read in, free egress - complies with EN1125 1. EL460 solenoid lock 2. CY326 singlecylinder - DIN Europrofile 3. DL8 door loop 4. PBE011-EL460 ABLOYpanic bar with 1/2 handle set 5. DC240 door closer (optional)
O R DE R IN G CODE S ABLOY-EL460- 30-PAC K 3P ABLOY-EL460- 35-PAC K 3P ABLOY-EL460-40-PAC K 3P ABLOY-EL460-45-PAC K 3P
Narrow stile door applications with handle operation, inside panic bar always operates and the outside handle is controlled and activated on signal from access control system. Key override at all times from outside. Technical Specification: Operating voltage: 12 V DC to 24 V DC stabilised ( + 15%-10%). Current draw: 12 V DC 350 mA max 24 V DC 250 mA max. Backsets available: 30 mm, 35 mm, 40 mm, 45 mm. Monitoring: RQE on panic bar, bolt position, door position, cylinder operation.
Standards: EN1125 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
13
ABLOY
Package4
Narrow stile door Read in, read out 1.
ORDERING CODES ABLOY-EL461-30-PACK4 ABLOY-EL461-35-PACK4 ABLOY-EL461-40-PACK4 ABLOY-EL461-45-PACK4
EL461 solenoid lock
2. 3.
CY327 double cylinder - DIN Europrofile
DL8 door loop
4. 60-0819-SSS handle set 3192750/PZ+PZ 5. DC240 door closer (optional) 6. 3192750/PZ+PZ (alternative) Narrow stile door applications with handle operation, both handles controlled and activated on signal from access control system. Key override at all times from both sides. Technical Specification: Operating voltage: 12 Voe to24 Voc stabilised (+15%-10%). Current draw: 12 Voe 350 mA max 24 Voe250 mA max. Backsets available: 30 mm, 35 mm, 40 mm, 45 mm. Monitoring: RQE on inside handle, bolt position, door position, cylinder operation.
Standards: EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
ABLOY
Package4M Multipoint
t
Narrow stile door Multipoint - Read in, read out
ORDERING CODES ABLOY-EL467-30-PACK4M ABLOY-EL467-35-PACK4M ABLOY-EL467-40-PACK4M ABLOY-EL467-45-PACK4M
1.
EL467 solenoid lock
2. 3. 4. 5. 6.
CY327 double cylinder - DIN Europrofile
DLB door loop
60-0819-SSS handle set to suite the EL461 & EL467
DC240 door closer (optional)
3192750/PZ+PZ (alternative)
Narrow stile door applications with handle operation, both handles controlled and activated on signal from access control system. Key override at all times from both sides. Technical Specification: Operating voltage: 12Voe to 24Voe stabilised (+15% -10%). Current draw: 12Voc350mAmax 24Voc250mAmax. Backsetsavailable: 30mm, 35mm, 40mm, 45mm. Monitoring: RQE on inside handle, bolt position, door position, cylinder operation.
Standards: EN1634-l EN61000-6-l EN 1303 (cylinder) EN14846
ORDERING CODES ABLOY-EL520-55-PACK5E ABLOY-EL520-60-PACK5E ABLOY-EL520-65-PACK5E
ORDERING CODES ABLOY-MP520-55-PACK5ME ABLOY-MP520-60-PACK5ME ABLOY-MP520-65-PACK5ME
ABLOY
E! Package 5MP
Multipoint - Escape - High Security
..
Standard door Read in, free egress (motor lock) - complies with EN1125 1. MP520 motor Lock 2. CY326 single cylinder - DIN Europrofile 3. EA280 concealed door Loop 4. PBE011-EL520 ABLOY panic bar with cylinder escutcheon 5. DC240 door closer (optional) High security wood or metal door applications with motor operated deadbolt, hook bolts and latch bolt, inside panic bar always operates. Key override at all times from outside. Technical Specification: Operating voltage: 12 VActo 18VAC, 12V DCto 24V DC (+15%-10%). Current draw: 12VDC 80 mA idle, norm 450 mA, max1430 mA 24 V Dc40 mA idle, norm 220 m A, max600 mA. Backsets available: Standard 65 mm, 55 mm, 60 mm. Monitoring: RQE on panic bar, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-MP520-55-PACK5MP ABLOY-MP520-60-PACK5MP ABLOY-MP520-65-PACK5MP
Standards: EN1125 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
II
ABLOY
E! Package5P
Escape - High Security
-
Standard door Read in, free egress (motor lock) - complies with EN1125 1. EL520 motor lock 2. CY326 singlecylinder - DIN Europrofile 3. EA280 concealed door loop 4. PBE011-EL520 ABLOY panic bar with cylinder escutcheon 5. DC240 door closer (optional) High security wood or metal door applications with motor operated deadbolt and latch bolt, inside panic bar always operates. Key override at all times from outside. Technical Specification: Operating voltage: 12 V AC to 18 V AC, 12 V DC to 24 V DC ( +15%-10%). Current draw: 12 V DC 80mA idle, norm 450mA, max 1430 mA 24 V DC 40mA idle, norm 220 mA, max 600 mA. Backsets available: Standard 65 mm, 55 mm, 60 mm. Monitoring: RQE on panic bar, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-EL520-55-PACK5P ABLOY-EL520-60-PACK5P ABLOY-EL520-65-PACK5P
Standards: EN1125 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
II
ABLOY
!J Package SE High Security
Narrow stile door Read in, free egress (motor lock) - complies with EN179 1. EL420 motor lock 2. CY326 single cylinder - DIN Europrofile 3. □ LB door loop 4. 60-0719-SSS handle and pullpad 5. DC240 door closer (optional) 6. 3192750/llSPZ+BL (alternative) High security narrow stile door applications with motor operated deadboltand late h bolt, inside handle always operates. Key override at all times from outside. Technical Specification: Operating voltage: 12 V AC to 18 V AC, 12Vocto 24Voc( + 15%-10%). Current draw: 12 Voe 80mA idle, norm 450 mA, max1300 mA 24 Voc40 mA idle, norm 220 mA, max600 mA. Backsets available: 30 mm, 35 mm, 40 mm, 45 mm. Monitoring: RQE on inside handle, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-EL420-30-PACK6E ABLOY-EL420-35-PACK6E ABLOY-EL420-40-PACK6E ABLOY-EL420-45-PACK6E
Standards: EN179 when used with correct furniture EN1634-l EN61000-6-l
E Nl3 03 (cylinder) EN14846
a
ABLOY
!J Package SME
Multipoint -High Security
Narrow stile door Read in, free egress (motor lock) -complies with EN179 1. MP420 motor lock 2. CY326 single cylinder - DIN Europrofile 3. □ LB door loop 4. 60-0719 handle and pullpad 5. DC240 door closer (optional) 6. 3192750/llSPZ+BL (alternative) High security narrow stile doorapplications with m otor operated deadbol t, h ook bolts and latch bolt, inside handle always operates. Key override atall times from outside. Technical Specification: Operating vol tage: 12VActo 18VAC, 12VDC to 24VDC (+15%-10%). Current draw: 12VDC 80mA idle, norm 450mA, max1300mA 24VDc40mA idle, norm 220mA,max600mA. Backsets available: 30mm, 35mm, 40mm, 45mm. Monitoring: RQE on inside handle, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-MP420-30-PACK6ME ABLOY-MP420-35-PACK6ME ABLOY-MP420-40-PACK6ME ABLOY-MP420-45-PACK6ME
Standards: EN179 when used with correct furniture EN1634-l EN61000-6-l
EN1303 (cylinder) EN14846
m
ABLOY
E! Package 6MP
Multipoint - Escape - High Security
j
a
Narrow stile door Read in, free egress (motor lock) - complies with EN1125 1. MP420 motor lock 2. CY326 single cylinder - DIN Europrofile 3. DLB door loop 4. PBE011-EL420 ABLOY panic bar with cylinder escutcheon 5. DC240 door closer (optional) High security narrow stile door applications with motor operated deadbolt, hook bolts and latch bolt, inside panic bar always operates. Key override at all times from outside. Technical Specification: Operating voltage: 12 V AC to 18 V AC, 12 V DC to 24 V DC ( +15%-10%). Current draw: 12 V DC 80 mA idle, norm 450 mA, max 1300 mA 24 V DC 40 mA idle, norm 220 mA, max 600 mA. Backsets available: 30 mm, 35 mm, 40 mm, 45 mm. Monitoring: RQE on panic bar, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-MP420-30-PACK6MP ABLOY-MP420-35-PACK6MP ABLOY-MP420-40-PACK6MP ABLOY-MP420-45-PACK6MP
Standards: EN1125 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
II
ABLOY
El Package6P
Escape - High Security
lj
•
a
•
u
Narrow stile door Read in, free egress (motor lock) - complies with EN1125 1. EL420 Lock case 2. CY326 singlecylinder - DIN Europrofile 3. DL8 door Loop 4. PBE011-EL420 ABLOY panic bar c / w cylinder escutcheon 5. DC240 door closer (optional) High security narrow stile door applications with motor operated deadbolt and lateh bolt, inside panic bar always operates. Key override at all times from outside. Technical Specification: Operating voltage: 12V AC to 18 V AC, 12Vocto 24Voc( + 15%-10%). Current draw: 12Voe 80mA idle, norm 450mA, max1300mA 24Voc40mA idle, norm 220mA, max600 mA. Backsets available: 30mm, 35mm, 40mm, 45mm. Monitoring: RQE on panic bar, bolt position, door position, cylinder operation. ORDERING CODES ABLOY-EL420-30-PACK6P ABLOY-EL420-35-PACK6P ABLOY-EL420-40-PACK6P ABLOY-EL420-45-PACK6P
Standards: EN1125 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
ABLOY
!J Package7E
Not suitable for Fire Rated doors
Narrow stile door Read in, free egress- complies with EN179 1. EL402 F/UN solenoid lock, fail unlocked 2. DLB door loop 3. CYOBO Scandinavian cylinder/push pad 4. DC240 door closer (optional)
ORDERING CODE ABLOY-EL402 F/UN-25-PACK7E ABLOY-EL402 F/UN-28-PACK7E ABLOY-EL402 F/UN-30-PACK7E ABLOY-EL402 F/UN-35-PACK7E
Narrow stile door applications with push pad operation and activated on signal from access control system. Key override at all times on outside, push pad always operational from inside. For use on aluminium doors; compliant with BS EN179 for emergency escape but not suitable for fire rated doors as they have not been fire tested. Technical Specification: Operating voltage: 12Vocor 24Voe stabilised ( + 15%-10%). Current draw: 12Voc480 mAmax 24Voc240 mA max. Backsets available: Adjustable from 25 mm, 28 mm, 30 mm, 35 mm or 35 mm. Monitoring: Bolt position.
Standards: EN179 when used with correct furniture EN61000-6-l EN1303 (cylinder)
ABLOY
n Package8E mm
D
Not suitable for Fire Rated doors
Standard door Read in, free egress- complies with EN179 1. EL502 F/UN solenoid lock, fail unlocked 2. EA280 concealed door loop 3. CYO??-PT-PC-DF Scandinavian cylinder/push pad 4. DC240 door closer (optional)
ORDERING CODE ABLOY-EL502 F/UN-50-PACK8E
Wood or metal door applications with push pad operation and activated on signal from access control system. Key override at all times on outside, push padalways operational from inside. For use on aluminium doors; compliant with BS EN179 for emergency escape but not suitable for fire rated doors as they have not been fire tested.
Technical Specification: Operating voltage: 12Vocor 24Voe stabilised (+15%-10%). Current draw: 12Voc480mA max 24Voc240 mA max.
Backset available: 50 mm. Monitoring: Bolt position.
Standards: EN179 when used with correct furniture EN61000-6-l EN1303 (cylinder)
ABLOY
!J Package SE
Standard door Read in, free egress - complies with EN179 1. EL580 solenoid lock 2. CY037 outside cylinder - Scandinavian 3. EA280 concealed door loop 4. 3-20/032 handle set 5. DC240 door closer (optional) 6. 60-0619-PSS (alternative)
ORDERING CODES ABLOY-EL580-50-PACK9E ABLOY-EL580-70-PACK9E
Wood or metal door applications with handle operation. Inside handle always operates and outside handle is controlled and activated on signal from access control system. Key override at all times.
Technical Specification: Operating voltage: 12 V DC to 24 V DC stabilised ( + 15%-10%). Current draw: 12 V Dc350 mA max 24 V Dc250 mA max.
Backsetavailable: Standard 50 mm, 70 mm. Monitoring: RQE on inside handle, bolt position.
Standards: EN179 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
ABLOY
E! Package SP
Escape (EN1125)
t,lj
Standard door Read in, free egress - complies with EN1125 1. PE580 solenoid Lock with LP712 strike 2. CY037 outside cylinder - Scandinavian 3. EA280 concealed door Loop 4. PBE00l Abloy panic bar 5. 3-20/0321 outside handle 6. DC240 door closer (optional)
O R D ER I N G COD E ABLOY-PE580-50-PACK9P
Wood or metal door applications with handle operation. Inside panic bar always operates and outside handle is controlled and activated on signal from access control system. Key override at all times.
Technical Specification: Operating voltage: 12 Voe to 24 Voe stabilised ( + 15%-10%). Current draw: 12 Voc 350 mA max 24Voe 250 mA max. Backset available: 50 mm. Monitoring: RQE on panic bar, bolt position.
Standards: EN1125 when used with correct furniture EN1634-l EN61000-6-l
EN1303 (cylinder) EN14846
a
ABLOY
!J Package 10 E
0
Narrow stile door Read in, free egress - complies with EN179 1. EL480 solenoid lock 2. CY063 outside cylinder - Scandinavian 3. DLB door loop 4. 3-20/0650 handle set 5. DC240 door closer (optional)
ORDERING CODES ABLOY-EL480-29-PACK10E ABLOY-EL480-35-PACK10E
Narrow stile door applications with handle operation. Inside handle always operates and outside handle is controlled and activated on signal from access control system. Key override at all times.
Technical Specification: Operating voltage: 12Vocto24Voe stabilised (+15%-10%). Current draw: 12Voc350mA max 24Voc250 mA max.
Backset available: Standard29 mm, 35 mm. Monitoring: RQE on inside handle, bolt position.
Standards: EN179 when used with correct furniture EN1634-l EN61000-6-l EN1303 (cylinder) EN14846
II
ABLOY
E! Package lOP Escape (EN1125)
Narrow stile door Read in, free egress - complies with EN1125 1. EL480 solenoid Lock 2. CY063 outside cylinder - Scandinavian 3. DLB door Loop 4. PBE00lAbloy panic bar 5. 3-20/0651 outside handle 6. DC240 door closer (optional)
ORDERING CODES ABLOY-EL480-29-PACK10P ABLOY-EL480-35-PACK10E
Narrow stile doar applications with handle operation. Inside handlealwaysoperates and outside handle is controlled and activated on signal from access control system. Key override at all times.
Technical Specification: Operating voltage: 12 Voe to 24 V oc stabilised ( + 15%-10%). Current draw: 12 Voe 350 mA max 24 Voe 250 mA max.
Backset available: Standard29 mm, 35mm. Monitoring: RQE on panic bar, bolt position. Standards: EN1125 when used with correct furniture EN1634-l EN61000-6-l
EN1303 (cylinder) EN14846
a
ORDERING CODE ABLOY-EL590-50-PACK11E
ABLOY
!l Package llP
Escape (EN1125)
Standard door Read in, free egress (motor lock) - complies with EN1125 1. PE590 motor lock 2. CY037 outside cylinder - Scandinavian 3. EA280 concealed door loop 4. PBE002Abloypanicbar 5. DC240 door closer (optional) High security wood or metal door applications with motor operated deadbolt and latch bolt, inside panic bar always operates. Key override at all times from outside. Technical Specification: Operating voltage: 12 V AC to 24 V DC stabilised (+15%-15%). Current draw: 12 V DC50 mA idle, norm 600 mA, max1700 mA 24 V Dc23 mA idle, norm 250 mA, max700 mA. Backsets available: Standard50 mm. Monitoring: RQE on panic bar, boltposition, cyl.operation with additional part 950885. ORDERING CODE ABLOY-PE580-50-PACK11P
Standards: EN1125 when used with correct furniture and functions EN1634-l EN61000-6-l
EN1303 (cylinder) EN14846
II
ABLOY
!J Package 12E High Security : . • !J • . ....
�
OD
(
' . ·u
Narrow stiledoor Readin, free egress (motor lock) - complies with EN179 1. 2. 3. CELY409603 mouottsoidr leoccyklinder - Scandinavian □ 4. 5. 3 D - C L 2 B 2 0 4 d / 0 o 0 o d 6 r o l 3 o o 0 r o c p in lo s s id er e ( h o a p n t d io l n e al) High security narrow stile door applicationswith motor operated deadbolt and latch bolt, inside handle always operates. Key override at all times from outside. Optional electrical handle control: if used negates EN179. ORDERING CODES ABLOY-EL490-29-PACK12E ABLOY-EL490-35-PACK12E
Technical Specification: Operating voltage: 12VActo24Vocstabilised (+15%-15%). Current draw: 12Voc50mA idle, norm 600mA, maxl700mA 24Voc23mAidle, norm 250mA, max700 mA. Backset available: Standard 29 mm, 35mm. Monitoring: RQE on inside handle, bolt position, cyl.operation.
Standards: EN179when used with correct furniture and functions EN1634-l EN61000-6-l
EN1303 (cylinder) EN14846
ORDERING CODES ABLOY-EL490-29-PACK12P ABLOY-EL490-35-PACK12P
ORDERING CODES ABLOY-EL418-30-PACK13E ABLOY-EL418-35-PACK13E ABLOY-EL418-40-PACK13E ABLOY-EL418-45-PACK13E
ORDERING CODES ABLOY-MP418-30-PACK13ME ABLOY-MP418-35-PACK13ME ABLOY-MP418-40-PACK13ME ABLOY-MP418-45-PACK13ME
ABLOY
El Package 13MP
Multipoint-Escape-High Sec-Not Fire Doors
I
Narrow stile door Read in, free egress (motor lock) - complies with EN1125 1. M P418 motor lock 2. CY326 singlecylinder - DIN Europrofile 3. DLB door loop 4. PBE011-EL420 Abloy panic bar c / w cylinder escutcheon 5. DC240 door closer (optional)
ORDERING CODES ABLOY-MP418-30-PACK13 M P ABLOY-MP418-35-PACK13 M P ABLOY-MP418-40-PACK13 M P ABLOY-MP418-45-PACK13 M P
High security narrow stile door applications with motor operated deadbolt, hook bolts and late h bolt, inside panic bar always operates. Key override at all times from outside.
Technical Specification: Operating voltage: 12VAc to 18 VAC, 12Voe to 24Voe (+15%-10%). Current draw: 12 Voe 80 mA idle, norm 450 mA, max 1300 mA 24 Voe 40 mA idle, norm 220 mA, max 600 mA. Backsets available: 30 mm, 35mm, 40mm, 45mm. Monitoring: Bolt position.
Standards: EN1125 when used with correct furniture EN61000-6-l EN1303 (cylinder) EN14846
ABLOY
E! Package 13P
Escape-High Security-Not for Fire Doors
----
D
u
Narrow stile door Read in, free egress (motor lock) - complies with EN1125 1. EL418 lock case 2. CY326 singlecylinder - DIN Europrofile 3. □ LB door loop 4. PBE011-EL420 Abloy Panic Bar with cylinder escutcheon 5. DC240 door closer (optional)
ORDERING CODES ABLOY-MP418-30-PACK13P ABLOY-MP418-35-PACK13P ABLOY-MP418-40-PACK13P ABLOY-MP418-45-PACK13P
High security narrow stile door applications with motor operated deadbolt and latch bolt, inside panic bar always operates. Key override at all times from outside.
Technical Specification: Operating voltage: 12VAc to 18VAC, 12Voc to 24Voc (+15%-10%). Current draw:12Voe 80mAidle, norm 450mA, max 1300mA 24Voc 40mA idle, norm 220mA, max 600 mA. Backsets available: 30mm, 35mm, 40mm, 45mm. Monitoring: Bolt position.
Standards: EN1125 when used with correct furniture EN61000-6-l EN1303 (cylinder) EN14846
ABLOY
1J Package 14E
High Security-Not for Fire Doors
Standard door Read in, free egress (motor lock) - complies with EN179 1. EL518 motor lock 2. CY326 singlecylinder - DIN Europrofile 3. EA280 concealed door loop 4. 319242/llSPZ+BL handle 5. DC240 door closer (optional) High security wood or metal door applications with motor operated deadbolt and latch bolt, inside handle always operates. Key override at all times from outside. Technical Specification: Operating voltage: 12 V AC to 18 V AC, 12Vocto 24Voc( + 15%-10%). Current draw: 12 Voe 80mA idle, norm 450mA 24Voc40mA idle, norm 220mA. Backsets available: Standard 65 mm, 55 mm, 60 mm. Monitoring: Bolt position. ORDERING CODES ABLOY-EL518-55-PACK14E ABLOY-EL518-60-PACK14E ABLOY-EL518-65-PACK14E
Standards: EN179when used with correct furniture EN61000-6-l EN1303 (cylinder) EN14846
ORDERING CODES ABLOY-MP518-55-PACK14ME ABLOY-MP518-60-PACK14ME ABLOY-MP518-65-PACK14ME
ABLOY
E! Package 14MP
Multipoint-Escape-High Sec-Not Fire Doors
Standard door Read in, free egress (motor lock) - complies with EN1125 1. MP518 motor Lock 2. CY326 single cylinder - DIN Europrofile 3. EA280 concealed door Loop 4. PBE011-EL520 Abloy panic bar with cylinder escutcheon 5. DC240 door closer (optional)
ORDERING CODES ABLOY- MP518-55-PACK14MP ABLOY-MP518-60-PACK14MP ABLOY-MP518-65-PACK14MP
High security wood or metal door applications with motor operated deadbolt, hook bolts and latch bolt, inside panic bar always operates. Key override at all times from outside.
Technical Specification: Operating voltage: 12 V AC to 18 V AC, 12 V DC to 24 V DC ( + 15%-10%). Current draw: 12V DC 80mA idle, norm 450mA, max 1430mA 24 V DC 40mA idle, norm 220mA, max 600mA. Backsets available: Standard 65mm, 55mm, 60mm. Monitoring: Bolt position.
Standards: EN1125 when used with correct furniture EN12209 EN61000-6-l
EN1303 (cylinder) EN14846
ABLOY
E! Package 14P
Escape-High Security-Not for Fire Doors
Standard door Read in, free egress (motor lock) -complies with E N1125 1. EL518 motor lock 2. CY326 singlecylinder - DIN Europrofile 3. EA280 concealed door loop 4. PBE011-EL520 Abloy panic bar with cylinder escutcheon 5. DC240 door closer (optional)
ORDERING CODES ABLOY-EL518-55-PACK14P ABLOY-EL518-60-PACK14P ABLOY-EL518-65-PACK14P
High security wood or metal door applications with motor operated deadbolt and latch bolt, inside panic bar always operates. Key override at all times from outside.
Technical Specification: Operating voltage: 12V AC to 18 V AC, 12Voc to 24Voc ( + 15%-10%). Current draw: 12Voc 80mA idle, norm 450mA, max 1430mA 24 Voe 40mA idle, norm 220mA, max 600mA. Backsets available: Standard 65mm, 55mm, 60mm. Monitoring: Bolt position.
Standards: EN1125 when used with correct furniture EN12209 EN61000-6-l
EN1303 (cylinder) EN14846
Electric Locking
35 1 M.80 Swing Door Lock
The electronic swing door strike 351M.80 is equipped with an innovative quiet electric motor drive and is designed for the locking of swing, double swing, and carousel doors. It is suitable for horizontal or vertical installation in the door frame. The door contact and the armature contact are designed as potential-free switching contacts. The door contact is switched magnetically when the door is closed. The armature contact can be used to monitor locking status. The 351M.80 swing door electric strike works according to the fail-safe unlocked operating principle. If the power is shut off or the power fails, the door can be opened. If power is connected and the door is in the "Door closed" position for at least 1 s Overview of Advantages Very quiet locking and unlocking, silent during permanent release Suitable e.g. for double-action swing doors and single-action swing doors, interlocking doors and special doors Suitable as a supplementary locking system for installation in fire doors Vertical and horizontal universal installation position in the door frame or in the door leaf Holding force of 5000 N Safe unlocking under pre-load of up to 5000 N
12V DC to 48V DC multi-voltage, controlled DC voltage Monitoring contact and armature contact integrated Compatible with Model 351U Scope of delivery Supplied with face and counter plate Note Suitable for fire doors according to British Standard BS476 Technical data DIN direction Universal Monitoring contact (RR) Yes Diode (05) Yes Armature monitoring contact Yes Fail-unlocked Yes Input operating voltage
12 to 48 V DC, controlled DC voltage
Max. current consumption with motor operation (approx. 1 s) 12 V DC Max. start current consumption with motor operation (approx. 1 s) 24 V DC Max. current consumption with motor operation (approx. 1 s) 48 V DC Max. current consumption in continuous operation 12 V DC Max. current consumption in continuous operation 24 V DC Max. current consumption in continuous operation 48 V DC
880 mA
520 mA
270 mA
480 mA
270 mA
150 mA
Max. pre-load
5000 N 5000 N
Break-in resistance Material housing
Stainless steel Operating temperature range -15 °C to +50 °C Bolt throw 10 mm Height 200 mm Width 25 mm Depth 42 mm material bolt Steel Rebate clearance
3 mm (2 mm – 4,5 mm)
Electric Locking
352M.80 Escape Door Lock
Very quiet locking and unlocking, silent during permanent release The 352M escape door lock is especially designed as an additiona s l i l locking sy stem to secure lock i ng s yste m to s ecure d oor s al on g es c ape rout es
Suitable as an additional locking element for instalation in fire doors Example for further usage options: double action swing door, revolving doors, i n ter locki ng door s , spe cial d oors Universal installation position, vertical and horizontal in the door frame Horodldoinogr lfeoarfce of 5000 N Safe unlocking under pre-load of up to 5000 N
12V DC to 24V DC multi-voltage, controlled DC voltage Monitoring contact and armature contact integrated Compatible for installation with models 351U and 351M Technical data DIN-direction Universal 12-24 V DC Monitoring contact (RR) Yes Diode (05) Yes Fail-unlocked Yes Armature monitoring contact Yes Input operating voltage 12-24 V DC ± 15% Max. current consumption with motor operation (approx. 2 s) 12 V DC 600 mA Max. current consumption with motor operation (approx. 2 s) 24 V DC 290 mA Current consumption in continuous operation (locked) 12 V DC 360 mA Current consumption in continuous operation (locked) 24 V DC 190 mA Approvals EltVTR|EN 13637 Max. pre-load 5000 N Break-in resistance 5000 N Operating temperature range -15 °C to +50 °C Installation position Vertical and horizontal Length 200 mm Width 25 mm Depth 42 mm material bolt Steel Rebate clearance 3 mm (2 mm – 4,5 mm)
Accessories/Individual parts Order number
Product
SET352E-25---00
Counterpart (VarioFix) with spacer plates Square-cut counterpart with VarioFix adjustment Spacer plate 3mm thickness, suitable for counterpart (VarioFix) Counterpart with spacer plates Round counterpart
352E-3-------00
SET352R-25---00
Article number
352M.80-----Q91
Electric Locking
EL 402 Electromechanical Lock
• Double action bolt • Bolt deadlocks when door closes • Bolt collapses into lockcase as door is opened (push or pull) • Key/thumbturn override at all times • Suitable for horizontal installation • Non-handed • Steel trigger and deadbolt
40
45
50
25
35
30
40/43/45/48/50
25/28/30/33/35 12
19
1.5
Ø5.5x2
24 23.5
15
ø8
24 47.5
4
129.5
153.5
TECHNICAL SPECIFICATION EL402
EL402 F/UN
13
225
200
Operating voltage +15%, -10% ±15%
14.5
12V DC stabilised 12V DC stabilised 24V DC stabilised 24V DC stabilised
Current max 12V DC
0.480mA 0.240mA
0.480mA 0.240mA
24V DC
Temperature (ºC)
-20 to +60
-20 to +60
Backset (mm) Standard
25
25
Special
30 or 35
30 or 35
25
Forend finish
Polished Chrome Polished Chrome
87
3
40
41.5
Electric Locking
EL 4 60 Handle Controlled Electric Lock
• Mechanical automatic locking system • Non handed, left / right • Exit side can be changed over • Can be changed between fail-unlocked & fail-locked • Burglary-resistant due to dead bolt with 20 mm throw • Exit function by inside handle • Suitable for fi re doors • Controllable outside handle • Mechanical override with cylinder • Monitoring functions • Door status • Handle down • Bolt deadlocked • Bolt in • Key cylinder used • Sabotage loop
Available Backsets : 30 mm, 35 mm, 40 mm, 45 mm
Ordered separately • Strike plate (e.g. EA330) • Cable EA218 (6m) / EA219 (10m) • Lead cover EA280/281
• Handle set (e.g. EH006/0750) and spindle • Split spindle EA288/289 with EL460/462 • Cylinder(s) (e.g. CY321T)
30 / 45 / 50 / 55 / 60 35 / 40 / 45
20.5
10.5
22 101 12 39 6
10.5
5.5
91
10
76
8 / 9
254
Technical data Handing Exit function
25
Non-handed, left/right
300
**
25
8.5
Yes (EL 4 60 )
21.5
8
Mechanical cylinder override
Yes
Latch
Double action latch
20
92 * (PZ) / 94 (RZ)
5.5 8
Dead bolt
Yes, 20mm 12-24 VDC
Input operating voltage Rated current consumption
35
12 V DC idle 240 mA, max. 550 mA 24 V DC idle 130 mA, max. 300 mA Max. 0.5 A 30 V AC/DC resist.10 W
22
17
Microswitch capacity (monitoring contacts)
8
15
Suitable for fi re doors
Yes
32
4.5 x 2
EN 1 4846:2008 EN 179:2008 EN 1125:2008
3S8D-L611
376B1342AB (EL 4 60 ) 376B1321AB (EL5 4 0 )
30
20
3
EL460
24 / 28
Electric Locking
EL 520 Motorised Electric Lock
•
Motorized bolt traction for push&pull and door automatics use
• •
Day/night mode
Electric anti-tampering: if deadbolt is thrown out when door is not closed, it is withdrawn in automatically. Mechanical automatic locking system
• • • • • • •
Non handed, left / right
Burglary-resistant due to dead bolt with 20 mm throw
Exit function by inside handle
Suitable for fire doors
Mechanical override with cylinder Back-up function: If deadbolt is withdrawn by motor and then power is cut, deadbolt is thrown out immediately (closed door) or allowed to throw out (when door is closed).
• • • • • • •
Monitoring functions
Door status Handle down
Bolt deadlocked
Bolt in
Key cylinder used
Sabotage loop
88 / 93 / 98 / 113 / 133
16.5
55 / 60 / 65 /80 / 100
Technical data Handing Exit function
Non-handed, left/right
57
Yes Yes
R 7
10
Mechanical cylinder override
168.5 66.5 72 * (PZ) / 74 (RZ) **
8 63
8 / 9 38
Latch
Double action latch
Dead bolt
Yes, 20mm 12-24 VDC 12-18 VAC
22
Input operating voltage
21.5
Rated current consumption
12 VDC idle 80mA, normal drive 450mA, max. 1300mA 24 VDC idle 40mA, normal drive 220mA, max. 600mA Max. 0.8 A 30 V AC/DC resist. 20 W
8
35 15
235
6 X 2
20
8
6
Relay capacity (monitoring contacts)
Suitable for fire doors
Yes
EN14846:2008 EN179:2008 EN1125:2008
3S8D-L611 376B1342AB 376B1321AB
35
6 x 2
20 / 24
38
3
35
Electric Locking
EL 5 60 Handle Controlled Electric Lock
• Mechanical automatic locking system • Non handed, left / right • Exit side can be changed over • Can be changed between fail-unlocked & fail-locked • Burglary-resistant due to dead bolt with 20 mm throw • Exit function by inside handle • Suitable for fi re doors • Controllable outside handle • Mechanical override with cylinder • Monitoring functions • Door status • Handle down • Bolt deadlocked • Bolt in • Key cylinder used • Sabotage loop
Available Backsets : 55mm, 60mm, 65mm,80mm 100mm
88 / 93 / 98 / 113 / 133
55 / 60 / 65 / 80 / 100
16.5
57
R7
10
66.5
63
8 / 9
22
38
Technical data Handing Exit function
Non-handed, left/right
**
21.5
Yes (EL560 )
168.5
8
35 15
Mechanical cylinder override
Yes
235
Latch
Double action latch
8
72 * (PZ) / 74 (RZ)
6 x 2
20
6
Dead bolt
Yes, 20mm 12-24 VDC
Input operating voltage Rated current consumption
12 V DC idle 240 mA, max. 550 mA 24 V DC idle 130 mA, max. 300 mA Max. 0.5 A 30 V AC/DC resist.10 W
8
35
Microswitch capacity (monitoring contacts)
Suitable for fi re doors
Yes
6 x 2
38
20 / 24
EN 1 4846:2008 EN 179:2008 EN 1125:2008
3S8D-L611
376B1342AB (EL560 ) 376B1321AB (EL560 )
3
EL560
35
Electric Locking
EL 5 6 1 Handle Controlled Electric Lock
• Mechanical automatic locking system • Non handed, left / right • Controlled handle both sides • Can be changed between fail-unlocked & fail-locked • Burglary-resistant due to dead bolt with 20 mm throw • Suitable for fi re doors • Controllable outside handle • Mechanical override with cylinder • Monitoring functions • Door status • Handle down • Bolt deadlocked • Bolt in • Key cylinder used • Sabotage loop
Available Backsets : 55mm, 60mm, 65mm,80mm 100mm
Ordered separately • Strike plate (e.g. EA324) • Cable EA218 (6m) / EA219 (10m) • Lead cover EA280/281 • Handle set (e.g. EH006/042) and spindle • Split spindle EA288/289 with EL560/562 • Cylinder(s) (e.g. CY321T)
88 / 93 / 98 / 113 / 133
55 / 60 / 65 / 80 / 100
16.5
57
R7
10
66.5
63
8 / 9
22
38
Technical data Handing Exit function
Non-handed, left/right
**
21.5
No
168.5
8
35 15
Mechanical cylinder override
Yes
235
Latch
Double action latch
8
72 * (PZ) / 74 (RZ)
6 x 2
20
6
Dead bolt
Yes, 20mm 12-24 VDC
Input operating voltage Rated current consumption
12 V DC idle 240 mA, max. 550 mA 24 V DC idle 130 mA, max. 300 mA Max. 0.5 A 30 V AC/DC resist.10 W
8
35
Microswitch capacity (monitoring contacts)
Suitable for fi re doors
Yes
6 x 2
38
20 / 24
EN 1 4846:2008
3S8D-L611
3
E L 561
35
Electric Locking
EL 5 8 0 Handle Controlled Electric Lock
ABLOY ELSS0, ELSS2 and PESSO are recommended to be used in the interior doors of business premises, public buildings, hospitals, educational premises etc. Typical applications are the doors of • offices • consulting rooms • storage rooms • fire doors (medium traffic) • technical maintenance rooms The locks are suitable to be used also in the exterior doors of residential buildings. They are best suited in medium traffic doors and can also be used in fire rated doors (EN). The locks are not suitable to be used with door automatics. ELSS0 and PESSO can be used in EXIT doors. Exit by inside handle/ panic bar is always possible. The locks are always automatically deadlocked when the door is closed. The locks can be controlled by a variety of remote control systems, i.e. card reader,keypad and timer.
TECHNICAL DETAILS
Operating voltage 12 - 24 V DC (-10%/+15%, stab.) Current max. 0.55A (12V DC) idle 0.3A (12V DC)
max. 0.27A (24V DC) idle 0.13A (24V DC)
Temperature range-25 - +70 ° C Bolt throw
14 or 20 mm (ELSS0,ELSS2) 14 mm (PESSO) 50,70 mm (ELSSO,ELSS2) 50 mm (PESSO) 22 mm S mm