2017_SBRT_Course Book
IMRT / VMAT with SIB in Patients with Brain Oligometastases
Author
Endpoint
PTV wb/dose PTV m/dose
Cases (lesions)
Main findings
Bauman 2007
WBRT +SIB (HT) vs WBRT + conventional SRT
30 (60)
14 (1-3)
SIB HT is a feasible alternative for SRT on small volume
Edwards 2010
WBRT + SIB(HT)
30 (40)
11 (1-4)
WBRT + SIB (HT) is feasible without adverse effects SIB-VMAT plans achieve adequate WBRT coverage with conformal hippocampal avoidance and RS quality dose distributions 60 Gy in 10 fract. To 1-3 brain metastases synchronously with 30 Gy WBRT 47.5 Gy in 5 fract.. Volumetric RS was effective for long term control
Hsu 2010
WBRT + SIB (VMAT) vs SRT
32.23 (63-70.8)
10 (1-3)
Rodrigues 2011
WBRT+ SIB (HT)
30 (35-60)
48 (1-3)
Nichol 2016
WBRT +VRS
20 (47.5 to metastases, 38 to 2 mm PTV)
60 (223)
Ferro 2017
WBRT + SIB (IMRT)
30 (35-50)
30 (1-5)
50 Gy in 10 fract. To 1-5 brain metastases synchron. With 30 Gy WBRT is feasible with IMRT