Table of Contents Table of Contents
Previous Page  7 / 31 Next Page
Information
Show Menu
Previous Page 7 / 31 Next Page
Page Background

918

T

hiex

:

J

ournal of

aoaC i

nTernaTional

V

ol

.

99, n

o

.

4, 2016

and mix by careful rotation and inversion. For liquid materials,

shake the laboratory sample vigorously to thoroughly mix.

Invert and rotate the container again (for solid materials) or

shake (for liquids) immediately before selecting a test portion.

Other validated sample preparation techniques that result in

a representative test portion are also acceptable. When the

analytical sample is split or the mass is reduced for any reason,

the splitting process should be validated to not introduce

unintended sampling error.

F. Extraction

Weigh a ~0.5 g test portion to the nearest 0.01 g (

see

Alternative A

, section

E

) and completely transfer to a 250 mL

wide-mouth class A volumetric flask. Dispense 100 mL

65 ± 2°C preheated citrate–EDTA extraction solution [

see

Alternative A

, section

C(m)

] into each flask and insert a

rubber stopper. Shake test solutions in a 65 ± 2°C preheated

water bath set to approximately 200 reciprocations/min for

60 ± 1 min, remove from the water bath, allow to cool to room

temperature (20–25°C), dilute to volume with deionized (or

equivalent) water, stopper, and mix. Filter any test solution

containing suspended debris using P- and K-free filters. Due

to a very limited shelf life, analyze test solutions within 16 h

of extraction. After repeated heating and cooling cycles of the

250 mL volumetric flasks, check the calibration of the flasks

by adding 250 g deionized (or equivalent) water and verify that

the volume is at the meniscus. When a flask loses calibration,

either use the corrected volume established by water weight,

or discard it.

G. ICP-OES Conditions

The optimal instrument conditions identified during method

validation of citrate–EDTA-soluble P and K are listed in

Table

2015.18D

. Monitor the rinse time and buffer concentration

closely, because they are sensitive to change (1).

ICP-OES instruments differ in their design and options, so

minor adjustment to the conditions listed in Table

2015.18D

may be necessary; however, any adjustments to these conditions

must be performance based and validated. Special attention

should be paid to the recovery of P in fertilizer concentrates or

fertilizers containing ≥40% P

2

O

5

, because these materials pose

the greatest need for optimal instrument performance.

H. Calculations

Several variables exist in the instrument software for data

reporting, including units, test portion weight, test solution

volume, and dilution factor. The calibration standards are

prepared as micrograms per milliliter P and K, and the final

fertilizer results are reported as percentage P

2

O

5

and K

2

O,

which requires the following two calculations, respectively:

P

2

O

5

, % = [P × (250/W) × 142/(31.0 × 2)]/10000

where P is the ICP-OES P reading in micrograms per milliliter,

250 is the final volume in milliliters, W is the test portion

weight in grams, 142 is the FW of P

2

O

5

, 31.0 is the FW of P,

2 is the mole ratio of P

2

O

5

to P, and 10000 is the conversion of

percentage to micrograms per milliliter; and

K

2

O, % = [K × (250/W) × 94.2/(39.1 × 2)]/10000

where K is the ICP-OES K reading in micrograms per milliliter,

250 is the final volume in milliliters, W is the test portion weight

in grams, 94.2 is the FW of K

2

O, 39.1 is the FW of K, 2 is

the mole ratio of K

2

O to K, and 10 000 is the conversion of

percentage to micrograms per milliliter.

Alternatively, the standards can be entered as equivalent

theoretical percentages of P

2

O

5

and K

2

O in solution values,

listed in Tables

2015.18A

and

2015.18B

.

When empirical calibration [

see Alternative A

, section

D(d)

]

is used, conversion of the percentage P

2

O

5

in the certified or

consensus material to milligrams per liter P in the calibration

solution is obtained by using the following equation:

P, g mL P O 10,000 W 250 31.0 2 142

2 5

(

)

(

) (

)

µ = % ×

×

×

×

where P, μg/mL is the P concentration in the extracted standard

solution; % P

2

O

5

is the certified or consensus value, 10000 is

the conversion of percentage to micrograms per milliliter, W

is the test portion weight in grams, 250 is the final volume in

milliliters, 31 is the FW of P, 2 is the mole ratio of P

2

O

5

/P, and

142 is the FW of P

2

O

5

.

I. Comments

Relative to other AOAC Methods (

960.03

,

978.01

,

and

993.01

), the ICP-OES method can produce lower P

recoveries and/or greater data variability

(http://www .magruderchecksample.org

). Critical factors and common

error sources are included here. For P, three issues are critical:

addressing matrix challenges, implementing robust plasma

conditions, and utilizing proper standards. Carbon in the citrate

and EDTA will reduce the plasma efficiency, so it must be

addressed. Diluting the matrix by using a smaller sample pump

Table 2015.18D. Final ICP-OES conditions used for

citrate–EDTA-soluble P and K validation

Factor

Setting

Power, kW

1.45

Plasma flow, L/min

19.5

Auxiliary flow, L/min

2.25

Nebulizer pressure, L/min

0.7

Nebulizer type

Seaspray

Spray chamber

Cyclonic

Sample pump tube

Black/black

a

Buffer/internal standard pump tube

Gray/gray

a

CsCl ionic buffer concn, M

0.018

Internal standard and concn, μg/mL

10

Buffer matrix

4% nitric acid

Exposure length, s

10

No. of exposures

3

Rinse time, s

35

Total analysis time, min

2

a

  An orange/white sample pump tube and a red/red buffer/internal 

standard pump tube provide approximately the same dilution factor, but 

use less volume of solution. Ensure that a sufficiently large waste pump 

tube is used to prevent flooding of the spray chamber.