TYPICAL WIRING

1F95-1280/1F95-1291

TYPICAL WIRING DIAGRAMS

Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer

Heat Pump Systems

Heat Pump Connections

Refer to equipment manufacturers’ instructions for specific system

wiring information.

You can configure the thermostat for use with the following heat pump

systems.

Single Stage and Multi-Stage Connections

Refer to equipment manufacturers’ instructions for specific system

wiring information.

This thermostat is designed to operate a single-transformer or two-

transformer system.

You can configure the thermostat for use with the following fossil fuel

systems:

Heat

Pump 1

(HP1)

Heat

Pump 2

(HP2)

System RC

RH

C

Y

Y2

*W/E

*W2

G

O

6

L

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

Heat mode-2nd

stage, Emergency

Mode-1st stage

*Note: Dual Fuel

option de-

energizes Heat

mode stage 1

(compressor)

when auxiliary

heat is energized

Heat mode-3rd

stage, Emergency

Mode-1st stage

*Note: Dual Fuel

option de-

energizes Heat

mode stages 1

and 2 (both

compressors)

when auxiliary

heat is energized

Heat mode-4th

stage, Emergency

Mode-2nd stage

*Note: Dual Fuel

option de-

energizes Heat

mode stages 1

and 2 (both

compressors)

when auxiliary

heat is energized

Heat mode-3rd

stage, Emergency

Mode-2nd stage

*Note: Dual Fuel

option de-

energizes Heat

mode stage 1

(compressor)

when auxiliary

heat is energized

24 volt

power for

cooling

24 volt

power for

heating

Heat mode-2nd

stage,

Cool mode-2nd

stage,

(Compressor)

No Output

24 volt

common

(optional

for system

operation,

required

for remote

sensor)

Heat mode-1st

stage,

Cool mode-1st

stage,

(Compressor)

Blower/Circulator fan

energized on a call

for cool or Fan On

(also energized in

heating if configured

for Electric Heat)

Installer

Configuration

Menu selects

“O” or “B” for

changeover

function.Set

to “O” terminal

energized in Cool

mode.Set to “B”

terminal

energized in Heat

& emergency

mode

Power closed

connection for

SPDT 3-wire

zone valve

“Call for Service”

(malfunction

indicator)

for Heat Pumps

with “L” terminal

connection.

Original production

1F95-1291’s

do not have this

connection

COOLING

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

HEATING

120VAC

*Dual fuel option, if selected turns off compressor(s) when Auxiliary stages energize.

Single stage (SS 1)

gas, oil or electric.

Multi-stage (MS 2)

gas, oil or electric.

After wiring, see INSTALLER CONFIGURATION section for proper

thermostat configuration.

HEAT PUMP TYPE 1 (HP 1)

.

Single stage compressor system;

gas or electric backup.

HEAT PUMP TYPE 2 (HP 2).

Multi-stage compressor or two

compressor system with gas or electric backup.

After wiring, see INSTALLER CONFIGURATION section for proper

thermostat configuration.

A1

Damper or

Economizer

Operation

(see configuration

menu item 31)

+

S

-

Supply voltage

to remote

temperature

sensor

Remote

temperature

sensor signal

Supply voltage

to remote

temperature

sensor

Remote Sensor Terminals

1F95-1280

Damper Terminal

Single Stage 1

(SS1)

Multi Stage 2

(MS2)

System

RC

RH

C

Y

Y2

W/E

W2

G

O/B

6

L

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

Call for heat

Heat mode-1st

stage

Heat mode-2nd

stage

No output

24 volt

power for

cooling

24 volt

power for

heating

Cool mode-2nd

stage

24 volt

common

(optional

for system

operation,

required

for remote

sensor)

Call for cool

No Output

Cool mode-1st

stage

Blower/Circulator fan

energized on a call

for cool or Fan On

(also energized in

heating if configured

for Electric Heat)

Installer

Configuration

Menu selects

“O” or “B” for

changeover

function. Set

to “O” terminal

energized in Cool

& Off mode. Set

to “B” terminal

energized in

Heat & emergency

mode

Power closed

connection for

SPDT 3-wire

zone valve

“Call for Service”

(malfunction

indicator) for

Heat Pumps

with “L” terminal

connection.

Original production

1F95-1291’s

do not have this

connection

A1

Damper or

Economizer

Operation

(see configuration

menu item 31)

+

S

-

Supply voltage

to remote

temperature

sensor

Remote

temperature

sensor signal

Supply voltage

to remote

temperature

sensor

1F95-1291 Humidification/De-humidification Terminals

HM

DHM

Humidification Terminal, Energizes on

call for heat if Humidity setpoint is

above room humidity. Can also be used

to provide humidification independent of

a call for heat and/or in cooling mode if

Automatic Humidification is selected in

Configuration Menu item #34

De-energizes on call for Dehumidifica-

tion to lower the fan speed. The DHM

terminal is only used on systems with a

compatible dehumidification feature that

have the required terminal connection

on the contol module or have a relay

installed to lower the fan speed