Parameter

Method Performance

Please

report in units as stated in SMPR!

Weighting

factor for

parameter

Suitability Ranking (1-

3-5)

(select from drop-down

list, 5 = best)

SPIFAN matrices

Applicable to all forms of infant, adult, and/or pediatric

formula (powders, ready-to-feed liquids, and liquid

concentrates).

Any combination of milk, soy, rice, whey, hydrolyzed protein,

starch, and amino acids, with and without intact protein.

Applicable to all forms of infant, andult and/or

pediatric formula. Any combination of milk, whey

hydrolyzed protein, starch and amino acids, with

and without intact protein.

1

5

All analytes defined in the

applicability statement are

measured.

Calcium, copper, iron magnesium, manganes, phosphorus,

potassium, sodium and zinc contents.

Calcium, copper, iron magnesium, manganes,

phosphorus, potassium, sodium and zinc contents.

1

5

Different analytical range per analyte!

Different analytical range per analyte!

0.001 (lower analytical range Mn) - 2000 (upper analytical

range K)

0.003 (lower analytical range Mn) - 1875 (upper

analytical range K)

* reconstituted final product

* reconstituted final product

Ca

0.1

Cu

0.002

Fe

0.09

K

2.6

Mg

0.03

Mn

0.001

Na

0.2

P

0.01

Zn

0.004

Ca

20

0.4

Cu

0.023

0.01

Fe

0.1

0.2

K

10

6

Mg

3

0.09

Mn

0.001

0.003

Na

10

0.5

P

15

0.04

Zn

0.4

0.01

Spike recovery (%)

90-110%

All recoveries are between 90.5% and 108.8%

2

5

Bias vs SRM

No requirement in SMPR

No Bias. See table 2 for all elements.

3

5

Ca

5%

0.82

Cu

5%

0.31

Fe

5%

0.70

K

5%

0.51

Mg

5%

0.85

Mn

5% - 8%

0.68

Na

5%

0.42

P

5%

0.65

Zn

5%

1.02

Ca

Cu

Fe

K

Mg

Mn

Na

P

Zn

Ca

8%

1.2

Cu

10%

1.7

Fe

10%

0.9

K

8%

1.4

Mg

10%

1.2

Mn

10% - 16%

1.4

Na

8%

1.2

P

8%

1

Zn

10%

1

5

5

5

5

5

5

5

5

b

Units

SMPR Requirement

Analytical Range.

1

Method Reference #

MTE3 (ISO/CD 15151 | IDF 229)

Method title:

Principle of the method:

Milk and milk products - Determination of calcium, copper, iron, magnesium, manganese, phosphorus, potassium, sodium and zinc contents - Indu

Determination of minerals total calcium, magnesium, phosphorus potassium and/or sodium and trace elements copper, iron, manganese and/or zinc in all forms of infa

Notes:

Overall Score

Not applicable

Intermediate Reproducibility

(RSDiR)

5

Recommendation of ERP

2 years after First Action Status

Laboratory safety

Other Considerations

Evaluation of Method Performance vs. SMPR requirements.

Feedback from Users of the Method since being awarded

First Action

Official Methods

Status

Repeatability (RSDr)

Reproducibility (RSDR)

Accuracy/Recovery

5

5

System is suitable

5

ADDITIONAL EVALUATION PARAMETERS

AOAC SMPR: 2014.004

Limit of detection (LOD)

1

a

Concentrations apply to (1) "ready to feed liquids" "as-is"; (2) reconstituted powders (25 g into 200 g water); and (3) liquid concentrates diluted 1:1 by weight.

Did Method Author Consider ERP’s Method Specific

Recommendations

(See web link to specific method

comments):

Decision by ERP

Yes. Improvements are made based on the ERP comments in March 2015.

Proprietary equipment

move to Final Action/repeal/remove/expand 2 year term

120

No unique proprietary equipment/accessories are required.

Method does not require any special safety precautions e.g. personal protection from highly toxic solvents.

3

1

2

5

5

No LOD requirement in SMPR

No requirement in SMPR

Bias against established method

Analytical equipment

1

Adequate proof of performance via system suitability

Is there a bias Yes/No ?

Analytical equipment is commonly available in most labs.

Limit of quantification (LOQ)

SPIFAN ERP Checklist v 1.6

27.06.2013