January 2017

39

www.read-eurowire.com

Technology

News

CANDOR Sweden AB

Tel: +46 11 21 75 00 Fax: +46 11 12 63 12

Email:

info@candorsweden.com www.candorsweden.com

Welding

wire copper

coating

Multi wire

cleaning

plant

• Electrolytic plating

• Candojet hot water cleaning

• Electrolytic & Ultrasonic degreasing

• Welding wire cleaning and copper coating

• Pickling & phosphating

Ultrasonic

& Electrolytic

ACCORDING to European standards, openly operated measuring and testing

equipment has to be checked regularly.

Therefore, spark testers are tested with regard to the accuracy of the supplied

high-voltage, the short circuit current and function (sensitivity).

The Sikora spark tester Spark 6030 HF offers (optionally) a three-step self-test and

calibration system including the Sikora App for mobile monitoring and analysis of

the measuring results. As each test probe has to be calibrated, the testing module

has to be controlled regularly as well.

To support this process, Sikora developed the module of the Spark 6030 HF further.

New is the easy-to-change module that combines all testing functions and which

can easily be exchanged from an additional opening in the housing of the Spark

6030 HF.

In order to meet the requirements of the ISO 9001 standards, Sikora recommends a

yearly calibration of the spark tester by simply exchanging the test module.

Due to the fact that all functions are directly mounted at the module, the complete

module is exchanged for calibration.

Therefore, a submission of the complete device to Sikora as well as the assignment

of a service engineer is not necessary.

As for the previous version of the module, the sensitivity and short circuit current

tests are generated. For the sensitivity test, 20 discharges are simulated in 20

seconds. All of these discharges have to be completely detected by the spark tester.

For the short circuit current test, an error caused by the contact of a user and the

bead chain electrode during the operation is simulated. Here, a defined value must

not be exceeded in order to guarantee the safety of the user.

The calibration module measures continuously the accuracy of the testing voltage.

The standard for spark testers requests an accuracy of ±5 per cent. The test is

successful if this criterion is met.

Sikora AG – Germany

Website

:

www.sikora.net

The spark tester Spark 6030 HF with removable self-test and calibration module

Sikora spark tester with