Background Image
Table of Contents Table of Contents
Previous Page  37 / 64 Next Page
Information
Show Menu
Previous Page 37 / 64 Next Page
Page Background

35

www.read-wca.com

Wire & Cable ASIA – January/February 2017

Technology

news

ACCORDING to European standards,

openly operated measuring and testing

equipment has to be checked

regularly. Therefore, spark testers are

tested with regard to the accuracy of

the supplied high-voltage, the short

circuit current and function (sensitivity).

The Sikora spark tester Spark 6030 HF

offers (optionally) a three-step self-test

and calibration system including the

Sikora App for mobile monitoring and

analysis of the measuring results. As

each test probe has to be calibrated,

the testing module has to be controlled

regularly as well.

To support this process, Sikora

developed the module of the Spark

6030 HF further. New is the

easy-to-change module that combines

all testing functions and which can

easily be exchanged from an additional

opening in the housing of the Spark

6030 HF.

In order to meet the requirements of

the ISO 9001 standards, Sikora

recommends a yearly calibration of the

spark tester by simply exchanging the

test module.

Due to the fact that all functions are

directly mounted at the module, the

complete module is exchanged for

calibration. Therefore, a submission of

the complete device to Sikora as well

as the assignment of a service

engineer is not necessary.

As for the previous version of the

module, the sensitivity and short

circuit current tests are generated.

For the sensitivity test, 20 discharges

are simulated in 20 seconds. All of

these discharges have to be

completely detected by the spark

tester.

For the short circuit current test, an

error caused by the contact of a user

and the bead chain electrode during

the operation is simulated. Here, a

defined value must not be exceeded in

order to guarantee the safety of the

user.

The calibration module measures

continuously the accuracy of the

testing voltage. The standard for spark

testers requests an accuracy of ±5 per

cent. The test is successful if this

criterion is met.

Sikora AG – Germany

Website

:

www.sikora.net

Tecno Impianti Srl of Italy is a major

designer and manufacturer of wire

drawing machinery for different sectors

of the wire industry.

Its newest feature is the redesign of its

successful wet wire drawing machine

Model TI-310. The machine is to be

utilised for production of CO

2

welding

wire. It will work with a horizontal

spooler and the line will be completed

with coppering tank and dancer.

The drawing machine Model TI-310 is

equipped with 11 wet drawing passes

plus one dry drawing pass at the

entrance, 310mm capstan and major

sized cone-holding shafts.

Tecno Impianti is also present in the

wire drawing machinery sector with

its TR Series of straight-line

multi-pass wire drawing machines,

the MV Series of vertical bull-blocks,

the inverted bull-block Model MVC

and the MO Series of horizontal-axis

wire drawing bull-blocks for CHQ

wire.

All its machines are designed and

manufactured by the company,

equipped with components of leading

brands and can be offered in many

different models and configurations,

with a tailor-made concept.

Tecno Impianti Srl – Italy

Website

:

www.tecnoimpianti-italy.com

Sikora spark tester with removable self-test module

www.aesa-cortaillod.com aesa@aesa-cortaillod.com

is introducing

a novel solution to measure the

Conductivity

Resistivity

for all types

of class 1 conductors

(round, sectoral,…)

Resistance & temperature with ResTest

Length with special ruler

Section by volume measurement

Automatically computed & displayed

Measurement in 3 steps

The spark tester Spark 6030 HF with removable self-test and calibration module

Redesign of a classic from Tecno Impianti